STC CURVE

The default STC curve can be maintained in most cases. If necessary the STC curve can be changed as follows:

1.Open the RADAR SETUP menu and select STC CURVE.

2.Press the A: EDIT soft key to show the setting window.

STC CURVE

NARROW

NORMAL

WIDE

E RETURN

STC curve setting window

3. Select STC curve;

NARROW:

The effective range of the [A/C SEA] adjustment is relatively short.

NORMAL:

Between NARROW and WIDE.

WIDE:

The effective range of the [A/C SEA] adjustment is relatively long.

4. Press the E: RETURN soft key to finish.

HEADING DATA

Select the heading reference, MAGNETIC or TRUE. Select MAGNETIC when connecting with a magnetic compass, or select TRUE when connecting with a true heading compass. For your reference, when connecting with the FURUNO Satellite Compass SC-60/120 or Integrated Heading Sensor PG-1000, set the heading data as in the table shown below.

 

Model

Setting of HEADING DATA

PG-1000

 

with L/L data

TRUE

 

w/o L/L data

MAGNETIC

 

 

SC-60/120

 

 

TRUE

1.Open the RADAR SETUP menu and then select HEADING DATA.

2.Press the A: EDIT soft key to show the setting window.

HEADING DATA

MAGNETIC

TRUE

Heading data setting window

3.Select MAGNETIC or TRUE.

4.Press the C: ENTER soft key.