Furuno GD-1900C-BB, 1953C-BB Setting up Data Ports, DATA1, DATA2 Port menus, Nmea data sentences

Models: GD-1900C-BB 1823C-BB 1953C-BB 1933C-BB 1833C-BB 1943C-BB

1 92
Download 92 pages 42.7 Kb
Page 60
Image 60

3.6Setting up Data Ports

Setup the data ports according to the equipment connected to them as follows.

1.Press the [MENU] key to open the menu.

2.Press the E: SYSTEM CONFIGURATION, C: SYSTEM SETUP and A: PORT SETUP soft keys.

3.Press the A: GPS/NMEA PORT soft key for DATA 1 port, or B: NMEA PORT soft key for DATA 2 port as appropriate. One of the following displays appears depending on your selection.

FURUNO GPS SENSOR

YES

 

OUTPUT FORMAT

NMEA0183

 

 

Ver 2.0

 

 

 

LAT/LON FORMAT

DD˚ MM.MMM'

 

OUTPUT DESTINATION

NO

 

 

 

 

WIRING INFORMATION TD-A >1>---WHITE TD-B >2>---BLUE RD-A>3>---YELLOW RD-B>4>---GREEN +12V>5>---RED

GND >6>---BLACK FG >7>---SHIELD

GPS/￿

PORT

A EDIT

SELECT

B SNTNC

E RETURN

 

 

 

NMEA￿

FURUNO GPS SENSOR

NO

PORT

OUTPUT FORMAT

NMEA0183

 

 

 

Ver 2.0

A EDIT

LAT/LON FORMAT

DD˚ MM.MMM'

OUTPUT DESTINATION

NO

SELECT

 

 

 

 

 

 

B SNTNC

WIRING INFORMATION

 

TD-A >1>---WHITE

E RETURN

TD-B >2>---BLACK

 

RD-A>3>---YELLOW

 

RD-B>4>---GREEN

 

NC

>5>

 

 

FG

>6>---SHIELD

 

DATA 1 port

DATA 2 port

DATA1, DATA2 PORT menus

4.Select item and press the A: EDIT soft key.

5.Set option referring to the table on page 3-17.

6.To select NMEA data sentences to output, press the B: SELECT SNTNC soft key.

For NETWORK port, select the sentence to output to the network equipment (default: all OFF).

AAM

--

APB

ON

BOD

--

BWR

--

DPT

--

GGA

--

GLL

ON

GTD

--

MTW

--

RMA

--

RMB

ON

RMC

ON

VHW

--

VTG

ON

WPL

--

XTE

--

ZDA

ON

HDT

--

HDG

--

MWV

--

TTM

--

 

 

SELECT SNTNC

A ON/OFF

E RETURN

AAM

--

APB

ON

BOD

--

BWC

--

DBT

--

GGA

--

GLL

ON

GTD

--

MTW

--

RMA

--

RMB

ON

RMC

ON

VHW

--

VTG

ON

WPL

--

XTE

--

ZDA

ON

HDT

--

HDG

--

MWV

--

TTM

--

 

 

SELECT SNTNC

A ON/OFF

E RETURN

NMEA Version 2.0 Range and bearing mode: Rhumb line

NMEA Version 1.5

Range and bearing mode: Great circle

NMEA data sentences

3-16

Page 60
Image 60
Furuno GD-1900C-BB, 1953C-BB, 1943C-BB, 1933C-BB manual Setting up Data Ports, DATA1, DATA2 Port menus, Nmea data sentences