qMain Menu → Record → Auto Delete Mode
The ADM feature prevents the unit from displaying or archiving any search results that are more than thirty days old. This feature may be required by law in some jurisdictions. Choose from 1 to 99 days or Off. The default setting is Off.
ADM Setting
Message
ADM will change. Are you sure?
99Days
Yes
3.11 Alarms
Use this menu to configure the alarm handling features of the unit.
Caution! The DVMRe Triplex’s primary function is to furnish video multiplexing and recording with a multiscreen display. Although the unit has alarm handling and motion detection functions, these are considered secondary features. This unit
should not be the only alarm device on site.
qMain Menu → Alarms → Input Configuration
Configure the alarm inputs as either Normally Open or Normally Closed. Configure inputs as follows.
Normally Open Zero Potential Relay Contact: Configure in menu as Normally Open.
Normally Closed Zero Potential Relay Contact: Configure in menu as Normally Closed
TTL Active High: Configure in menu as Normally Closed.
TTL Active Low: Configure in menu as Normally Open.
Open Collector Active On: Configure in menu as Normally Open.
Open Collector Active Off: Configure in menu as Normally Closed.
Input Configuration
Alarm Latch
Alarm Action Alarm Record Mode Enable / Disable Alarm History Link to a Macro Fullscreen Alarm Relay Configuration Buzzer Setup Videoloss Action Pre Alarm Duration Notification Archive Alarms
41 | DVMRe Triplex |