GE 0150-0193G manual View Screens

Models: 0150-0193G

1 94
Download 94 pages 14.58 Kb
Page 64
Image 64

View Screens 1 through 10: These menus provide an overview of the units current operating parameters and the menu settings selected by the user or installer. Each View Screen is described in the following tables. The default values are bolded and italicized.

The View Screens

View Screen 1

Alarm Input

Enable/Disable: 1 = Enabled, 0 = Disabled

Normally Open or Normally Closed: 0 = Open, C = Closed

Macro: Macro number if activated.

Alarm Action

Freeze: 1 = Freeze, 0 = No Freeze

Cameras: Primary camera in alarm and three associated cameras.

Relay: 1, 2, 1+2, or None.

Intrusion AND/OR: AND, OR

View Screen 2

Camera

Enable/Disable: 1 = Enabled, 0 = Disabled

Signal Gain: AGC setting from 1 through 100. 50

Covert Camera: Yes or No

Camera Title: Camera x, x=number

Videoloss Action

Relay 1: 1 = Enabled, 0 = Disabled

Relay 2: 1 = Enabled, 0 = Disabled

Buzzer: 1 = Enabled, 0 = Disabled

View Screen 3

Motion Detection

Enable/Disable: 1 = Enabled, 0 = Disabled

Activity or Intrusion Detection: I = Intrusion, A = Activity

Sensitivity: 1 through 10, 5

Relay Output: None, 1, 2, 1+2

Link to Event: Yes or No

Rejection Ratio: High, Medium, or Low

Target Size: 1 through 256

Alarm Camera: 1 through 4, 10 or 16

0150-0193G

64

DVMRe Triplex

Page 64
Image 64
GE 0150-0193G manual View Screens