To replace the lower inner door assembly:

To replace the lower inner door assembly:

1.Remove the outer door assembly. (See Door Assemblies.)

2.Remove the four T15 Torx screws (2 on each side) that attach each door hinge to the inner door. Carefully turn the door over and remove both door hinges.

3.Remove the six 1/4-in. hex-head screws that hold the insulation retainer to the inner door. Remove the insulation retainer.

4.Remove the insulation and the inner glass assembly from the inner door.

Inner Glass Assembly

To remove the upper outer door assembly:

1.Remove the upper door. (See Door Assemblies.)

2.Place the inner door assembly, gasket side up, on a protective surface.

3.Remove the two T15 Torx screws from the bottom of the outer door assembly.

4. Remove the two T15 Torx screws (1 on each side) from the outer door assembly.

1 of 2

Note: The inner door assembly is heavier than the outer door assembly.

5.Separate the inner door assembly from the outer door assembly.

6.Remove the four 1/4-in. hex-head screws and brackets that hold the door handle to the outer door assembly.

Door Shown with Inner Door Assembly Removed

Outer Door Assembly

Caution: Care must be taken if reinstalling the door handle. Overtightening the screws can damage the handle. Hand-tighten the screws and make sure the handle fits snugly to the door panel. (Do not use an electric driver.)

(Continued next page)