Installation Instructions

Dryer

DPVH890 and UPVH890

Questions? Call 800.GE.CARES (800.432.2737) or visit our Web site at: ge.com In Canada, call 1.800.561.3344 or visit geappliances.ca

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANTSave these instructions for local electrical inspector’s use.

IMPORTANTObserve all governing codes and ordinances.

Install the clothes dryer according to the manufacturer’s instructions and local codes.

Note to Installer – Be sure to leave these instructions with the Consumer.

Note to Consumer – Keep these instructions for future reference.

Clothes dryer installation must be performed by a qualified installer.

This dryer must be exhausted to the outdoors.

Before the old dryer is removed from service or discarded, remove the dryer door.

Service information and the wiring diagram are located in the control console.

Do not allow children on or in the appliance. Close supervision of children is necessary when the appliance is used near children.

Proper installation is the responsibility of the installer.

Product failure due to improper installation is not covered under the Warranty.

To reduce the risk of severe injury or death, follow all installation instructions.

FOR YOUR SAFETY:

WARNING Risk of Fire

Use only rigid metal or flexible metal 4-inch diameter ductwork for exhausting to the outdoors. Never use plastic or other combustible easy-to-puncture ductwork.

Do not install a clothes dryer with flexible plastic venting materials. If flexible metal (foil type) duct is installed, it must be of a specific type identified by the appliance manufacturer as suitable for use with clothes dryers. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct clothes dryer airflow and increase the risk of fire.

This appliance must be properly grounded and installed as described in these instructions.

Do not install or store appliance in an area where it will be exposed to water and/or weather.

The National Fuel Gas Code restricts installations of gas appliances in garages. They must be 18 inches off the ground and protected by a barrier from vehicles.

Install the dryer where the temperature is above 50°F for satisfactory operation of the dryer control system.

FOR GAS MODELS ONLY:

NOTE: Installation and service of this dryer must be performed by a qualified installer, service agency or the gas supplier.

In the Commonwealth of Massachusetts:

This product must be installed by a licensed plumber or gas fitter.

When using ball-type gas shut-off valves, they shall be T-handle-type.

A flexible gas connector, when used, must not exceed 3 feet.

13

Page 13
Image 13
GE installation instructions DPVH890 and UPVH890, Before YOU Begin, For Your Safety, For GAS Models only

UPVH890 specifications

The GE UPVH890 is a state-of-the-art ultrasound machine that redefines imaging capabilities in the medical field. It is designed for comprehensive diagnostic applications, emphasizing portability, versatility, and advanced imaging technologies. This device stands at the intersection of functionality and user-friendliness, making it a valuable asset in various healthcare settings, from hospitals to outpatient clinics.

One of the main features of the UPVH890 is its lightweight design. Weighing significantly less than traditional ultrasound machines, it offers unparalleled portability, allowing healthcare providers to transport it easily from room to room or even to remote locations. This is particularly advantageous in emergency situations where rapid ultrasound assessments are crucial.

The UPVH890 employs cutting-edge imaging technologies, including advanced three-dimensional and four-dimensional imaging capabilities. These features enable clinicians to visualize complex anatomical structures in real-time, enhancing diagnostic accuracy. The system is equipped with enhanced Doppler imaging, crucial for evaluating blood flow, and provides high-resolution images that aid in better assessment of conditions.

Additionally, the device incorporates artificial intelligence (AI) algorithms, which streamline the workflow and improve image interpretation. The built-in AI assists clinicians by providing automated measurements and suggesting the most likely diagnosis based on the obtained data, ultimately leading to quicker and more accurate patient care.

The UPVH890 also boasts an intuitive touchscreen interface that facilitates easy navigation through various settings and functions. This feature reduces the learning curve for new users and enhances efficiency for experienced operators. The customizable user interface allows healthcare providers to tailor the machine's settings according to their specific preferences and the needs of their patients.

In terms of connectivity, the UPVH890 supports wireless communication, enabling seamless integration with electronic medical record (EMR) systems. This capability ensures that patient information is readily available, promoting coordinated care and efficient follow-up processes.

Overall, the GE UPVH890 ultrasound machine stands out for its innovative features, intelligent technologies, and user-centric design that collectively enhance diagnostic efficiency and patient care. It represents a significant advancement in the field of medical imaging, catering to a wide range of clinical needs while ensuring ease of use and accessibility.