Installation Instructions

STACKING THE WASHER AND DRYER (if desired)

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANTSave these instructions for local electrical inspector’s use.

IMPORTANTObserve all governing codes and ordinances.

Note to Installer – Be sure to leave these instructions with the Consumer.

Note to Consumer – Keep these instructions for future reference.

Service must be performed by a qualified installer.

Proper installation is the responsibility of the installer.

FOR YOUR SAFETY:

WARNING –

Electric Shock Hazard. Disconnect power before installing. Failure to do so could result in serious injury or death.

Potential Personal Injury. More than two people are recommended to lift the dryer into position because of its weight and size. Failure to do so could result in personal injury or death.

Avoid Tipping and Rupture of Utility Services. Dryer must be securely attached to the washer. DO NOT place the washer on top of the dryer. Failure to do so could result in personal injury/death or property damage.

Mobile Home or Manufactured Home Installation – Stacking of a gas dryer is not permitted in a mobile home or manufactured home.

MINIMUM CLEARANCE OTHER THAN ALCOVE OR CLOSET INSTALLATION

Minimum clearance to combustible surfaces and for air opening are: 0both sides, 1front and 3rear. Consideration must be given to provide adequate clearance for installation and service.

REQUIREMENTS FOR ALCOVE OR CLOSET INSTALLATION

Your dryer is approved for installation in an alcove or closet, as stated on a label on the dryer back.

The dryer MUST be vented to the outdoors. See the EXHAUSTING THE DRYER section.

Minimum clearance between dryer cabinet and adjacent walls or other surfaces is:

0either side

3front and rear

Minimum vertical space from floor to overhead shelves, cabinets, ceilings, etc., is 52.

Closet doors must be louvered or otherwise ventilated and have at least 60 square inches of open area equally distributed. If the closet contains both a washer and a dryer, doors must contain a minimum of 120 square inches of open area equally distributed.

The closet should be vented to the outdoors to prevent gas pocketing in case of gas in the supply line.

No other fuel-burning appliance shall be installed in the same closet with the dryer (gas models only).

NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT THE REAR OF THE DRYER, MINIMUM CLEARANCE FROM THE WALL IS 5.5 INCHES.

38

Page 38
Image 38
GE UPVH890 installation instructions Before YOU Begin

UPVH890 specifications

The GE UPVH890 is a state-of-the-art ultrasound machine that redefines imaging capabilities in the medical field. It is designed for comprehensive diagnostic applications, emphasizing portability, versatility, and advanced imaging technologies. This device stands at the intersection of functionality and user-friendliness, making it a valuable asset in various healthcare settings, from hospitals to outpatient clinics.

One of the main features of the UPVH890 is its lightweight design. Weighing significantly less than traditional ultrasound machines, it offers unparalleled portability, allowing healthcare providers to transport it easily from room to room or even to remote locations. This is particularly advantageous in emergency situations where rapid ultrasound assessments are crucial.

The UPVH890 employs cutting-edge imaging technologies, including advanced three-dimensional and four-dimensional imaging capabilities. These features enable clinicians to visualize complex anatomical structures in real-time, enhancing diagnostic accuracy. The system is equipped with enhanced Doppler imaging, crucial for evaluating blood flow, and provides high-resolution images that aid in better assessment of conditions.

Additionally, the device incorporates artificial intelligence (AI) algorithms, which streamline the workflow and improve image interpretation. The built-in AI assists clinicians by providing automated measurements and suggesting the most likely diagnosis based on the obtained data, ultimately leading to quicker and more accurate patient care.

The UPVH890 also boasts an intuitive touchscreen interface that facilitates easy navigation through various settings and functions. This feature reduces the learning curve for new users and enhances efficiency for experienced operators. The customizable user interface allows healthcare providers to tailor the machine's settings according to their specific preferences and the needs of their patients.

In terms of connectivity, the UPVH890 supports wireless communication, enabling seamless integration with electronic medical record (EMR) systems. This capability ensures that patient information is readily available, promoting coordinated care and efficient follow-up processes.

Overall, the GE UPVH890 ultrasound machine stands out for its innovative features, intelligent technologies, and user-centric design that collectively enhance diagnostic efficiency and patient care. It represents a significant advancement in the field of medical imaging, catering to a wide range of clinical needs while ensuring ease of use and accessibility.