Grounding

Converting to 440V

 

 

 

 

 

 

Electrocution or fire could result if this machine is not grounded correctly. Make sure all electrical cir- cuits are grounded before you connect them to the machine. DO NOT use the Model G0504 if it is not grounded.

In the event of an electrical malfunction or break- down, grounding provides a path of least resis- tance for electric current to reduce the risk of electric shock. This machine must be equipped with an electric cord that has an equipment grounding conductor. This conductor must be grounded in accordance with all local codes and ordinances.

Improper connections of the electrical-grounding conductor can result in the risk of electric shock. Check with a qualified electrician or one of our service personnel if the grounding instructions are not completely understood, or if you are in doubt as to whether the machine is properly grounded.

-10-

Converting the Model G0504 to 440V operation consists of 1) wiring the voltage transformer, 2) replacing the overload relays with those provided in the G0504 440V conversion kit, and 3) rewiring the main motor and the elevation motor. A quali- fied electrician must inspect all electrical modifi- cations before connecting to power.

Voltage Transformer

Main Motor Relay

Figure 3. Inside of electrical box.

To convert the Model G0504 to 440V:

1.Disconnect the resaw from the power source!

2.At the voltage transformer, move the T1 wire from the 220V terminal to the 440V terminal.

Figure 4. Location on voltage transformer to

move the T1 wire for 440V operation. G0504 16" Horizontal Resaw Bandsaw