SECTION 3: CIRCUIT REQUIREMENTS

3-Phase Power

Serious personal injury could occur if you allow power to the machine before complet- ing the setup process. DO NOT allow power to the machine until instructed to do so.

Amperage Draw

The Model G0504 features a 220/440V motor that is prewired for 220V and draws the following amps under maximum load:

Motor Draw at 220V

62.2

Amps

Motor Draw at 440V

31.1

Amps

Circuit Requirements

We recommend connecting your machine to a dedicated and grounded circuit that is rated for the amperage given below. Never replace a circuit breaker on an existing circuit with one of higher amperage without consulting a quali- fied electrician to ensure compliance with wir- ing codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared circuit, consult a qualified electrician.

220V Circuit

80 Amps

440V Circuit

40 Amps

A fire may occur if your particular electrical configuration does not comply with local and state codes. The best way to ensure compli- ance is to check with your local municipality or a qualified electrician.

Connection Type

This machine is intended to be installed in a semi-permanent location and hardwired to the power source by a qualified electrician, using a supply circuit disconnect device with the capa- bility of being locked in the OFF (open) position (see Figure 1).

Figure 1. A power disconnect is preferable to

high current plugs and receptacles.

Figure 2. Power connection points inside the

electrical box.