![](/images/new-backgrounds/1146741/14674113x1.webp)
SECTION 2: CIRCUIT REQUIREMENTS
110V Operation |
| Extension Cords |
|
|
|
|
|
|
The Model G0516 Lathe/Mill is wired for 110V
If you operate this lathe/mill on any circuit that is already close to its capacity, it might blow a fuse or trip a circuit breaker. However, if an unusual load does not exist and a power failure still occurs, contact a qualified electrician or our ser- vice department.
The Model G0516 is equipped with its own fuses to prevent overload damage. When replacing these fuses please replace with the following:
Lathe | 25A | Fuse |
Mill/Drill | 5A | Fuse |
NOTICE
The Model G0516 cannot be rewired for 220V operation! Attempting to do this will void the warranty and will ruin the machine.
If you find it necessary to use an extension cord with the Model G0516, make sure the cord is rated Hard Service (grade S) or better. Refer to the chart in the standard safety instructions to determine the minimum gauge for the extension cord. The extension cord must also contain a ground wire and plug pin. Always repair or replace extension cords when they become worn or damaged.
G0516 Lathe/Mill |