SECTION 2: CIRCUIT REQUIREMENTS

Operation

Serious personal injury could occur if you connect the machine to power before com- pleting the setup process. DO NOT connect the machine to the power until instructed later in this manual.

Electrocution or fire could result if machine is not grounded and installed in compliance with electrical codes. Compliance MUST be verified by a qualified electrician!

Full Load Amperage Draw Draw

G0605X @ 220V

23 Amps

G0606X @ 220V

19 Amps

G0606X @ 440V*

10 Amps

Circuit Requirements

You MUST connect your machine to a grounded circuit that is rated for the amperage given below. Never replace a circuit breaker on an existing cir- cuit with one of higher amperage without consult- ing a qualified electrician to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to con- nect your machine to a shared circuit, consult a qualified electrician.

G0605X @ 220V

30 Amps

G0605X @ 220V

30 Amps

G0606X @ 440V

15 Amps

-12-

Power Connection Device

The power connection device depends on the type of installed or planned service. We recom- mend using one of the devices shown in Figure 2, depending on the voltage being used.

G0605X @220V Single-Phase

L6-30

G0606X @220V 3-Phase

.........................

L15-30

G0606X @440V 3-Phs

Hardwired

Locking

Disconnect Switch

 

 

For 440V connections, an electrician MUST hardwire the machine (using a metal conduit setup) directly to a locking disconnect switch, which is directly connected to the power source.

L6-30

Plug & Outlet

for 220V, Single-

Phase

L15-30

Plug & Outlet

for 220V, 3-Phase

Hardwired Locking

Disconnect Switch

for 440V, 3-Phase

�������

�������

��

��

�������

������������

 

Figure 2. Recommended connection types.

G0605X/G0606X Extreme Series 12" Table Saw

Page 14
Image 14