SECTION 2: CIRCUIT REQUIREMENTS
Operation
Serious personal injury could occur if you connect the machine to power before com- pleting the setup process. DO NOT connect the machine to the power until instructed later in this manual.
Electrocution or fire could result if machine is not grounded and installed in compliance with electrical codes. Compliance MUST be verified by a qualified electrician!
Full Load Amperage Draw Draw
G0605X @ 220V | 23 Amps |
G0606X @ 220V | 19 Amps |
G0606X @ 440V* | 10 Amps |
Circuit Requirements
You MUST connect your machine to a grounded circuit that is rated for the amperage given below. Never replace a circuit breaker on an existing cir- cuit with one of higher amperage without consult- ing a qualified electrician to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to con- nect your machine to a shared circuit, consult a qualified electrician.
G0605X @ 220V | 30 Amps |
G0605X @ 220V | 30 Amps |
G0606X @ 440V | 15 Amps |
Power Connection Device
The power connection device depends on the type of installed or planned service. We recom- mend using one of the devices shown in Figure 2, depending on the voltage being used.
G0605X @220V | ||
G0606X @220V | ......................... | |
G0606X @440V | Hardwired | Locking |
Disconnect Switch |
|
|
For 440V connections, an electrician MUST hardwire the machine (using a metal conduit setup) directly to a locking disconnect switch, which is directly connected to the power source.
Plug & Outlet
for 220V, Single-
Phase
Plug & Outlet
for 220V,
Hardwired Locking
Disconnect Switch
for 440V,
������� | ������� | |
�� | ||
�� | ||
������� | ||
������������ | ||
|