Recommended
Adjustments
The adjustments listed below have been per- formed at the factory and no further setup is required to operate the machine.
However, because of the many variables involved with shipping, we recommend checking the fol- lowing adjustments to ensure the best possible results from your new machine:
Recommended adjustment checklist:
•Blade Tilt Stops on Page 50
•Miter Slot to Blade Parallelism on Page 52
Test Run
Once the assembly is complete, test run your machine to make sure it runs properly for regular operations.
The test run consists of verifying the following:
1)The motor powers up and runs correctly, and
2)the safety disabling mechanism on the switch works correctly, and 3) to check for unusual noises or vibration.
If, during the test run, you cannot easily locate the source of an unusual noise or vibration, stop using the machine immediately, then review the Troubleshooting on Page 46.
If you still cannot remedy a problem, contact our Tech Support at (570)
To test run the machine:
1.Read this manual and make sure you under- stand SECTION 1: SAFETY on Page 7.
2.Review CIRCUIT REQUIREMENTS on Page 12, and make any necessary changes.
3.Make sure the blade guard and splitter (or riving knife) are installed and correctly adjust- ed.
G0605X/G0606X Extreme Series 12" Table Saw
4.Remove all tools and foreign objects from the machine.
5.Connect the tablesaw to the power source.
6.Put on safety glasses and hearing protec- tion, and make sure any bystanders are wearing safety glasses, hearing protection, and are out of the way.
7.Make sure the safety pin is not installed.
8.Keep a finger on the STOP paddle (Figure 30) at all times during the test run.
9.Verify that the machine is operating correctly by pressing the ON button.
10.Lift the paddle switch and insert the safety pin through the ON button.
11.Press the ON button.
—If the saw does not start, the safety dis- abling feature is working correctly.
—If the saw starts, immediately press the OFF button and DISCONNECT THE SAW FROM THE POWER SOURCE. The safety disabling feature is not working correctly. Please contact our Technical Support at (570)