Extension Cords (220V Only)

Using extension cords may reduce the life of the motor. Instead, place the machine near a power source. If you must use an extension cord:

Use at least a 10 gauge cord that does not exceed 50 feet in length.

Ensure that the extension cord contains a ground wire and plug pin.

Phase Converter Precaution

The power from the manufactured leg may dam- age electrical components if connected to the wrong incoming power terminal on your machine. Only connect the manufactured leg to the L3 ter- minal (see Page 59 for identification).

G0605X/G0606X Extreme Series 12" Table Saw

440V Conversion

The Model G0606X can be converted for 440V operation. This conversion job consists of discon- necting the saw from the power source, rewiring the motor, switching the transformer fuse from 220V to 440V, and changing the thermal overload relay from 22 to 11 Amps. Refer to the wiring dia- gram and photos on Page 60 and 58 for wiring details.

All wiring changes must be inspected by a quali- fied electrician before the saw is connected to the power source. If, at any time during this procedure you need help, call Grizzly Tech Support at (570) 546-9663.

-13-

Page 15
Image 15
Grizzly G0605X/G0606X owner manual 440V Conversion, Extension Cords 220V Only, Phase Converter Precaution