GSI Outdoors PNEG-377 service manual High Temperature Heater Specifications

Models: PNEG-377

1 98
Download 98 pages 21.15 Kb
Page 27
Image 27
High Temperature Heater Specifications

Fan and Heater VANE AXIAL GAS HEATER SPECIFICATONS

High Temperature Heater Specifications

 

 

18"

24"

26"

28"

 

 

 

 

 

 

All models

Inside diameter

18.5/16"

24.1/4"

26.5/16"

28.1/8"

 

Bolt circle diameter

19.7/16"

25.3/4"

27.15/16"

29.5/8"

 

Length

22"

22.1/2"

22.1/4"

25.1/4"

 

BTU rating

1400000

2100000

2700000

3000000

 

Weight

81

110

115

140

 

 

 

 

 

 

Liquid models

Maximum fuel flow (GPH)

N/A

23

30

34

 

Orifice

N/A

3/16"

7/32"

15/64"

 

Minimum operating pressure

N/A

2

2

2

 

Maximum operating pressure

N/A

20

20

20

 

Minimum line size

N/A

3/8"

3/8"

3/8"

 

 

 

 

 

 

 

Maximum fuel flow (CFH)

585

877

1128

1253

Vapor models

Orifice

5/32"

3/16"

7/32"

15/64"

 

Minimum operating pressure

2

2

2

2

 

Maximum operating pressure

20

20

20

20

 

Minimum line size

1/2"

3/4"

3/4"

3/4"

 

 

 

 

 

 

 

Maximum fuel flow (CFH)

1473

2210

2842

3157

 

Orifice

1/4"

5/16"

23/64"

3/8"

Natural gas

Minimum operating pressure

1

1

1

1

models

Maximum operating pressure

7

7

7

7

 

Minimum line size

3/4"

1"

1.1/4"

1.1/4"

 

 

 

 

 

 

Low Temperature Heater Specifications

 

 

18"

24"

26"

28"

 

 

 

 

 

 

All models

Inside diameter

18.5/16"

24.1/4"

26.5/16"

28.1/8"

 

Bolt circle diameter

19.7/16"

25.3/4"

27.15/16"

29.5/8"

 

Length

22"

22.1/2"

22.1/4"

25.1/4"

 

BTU rating

400000

500000

500000

500000

 

Weight

81

110

115

140

 

 

 

 

 

 

Vapor models

Maximum fuel flow (GPH)

167

292

292

292

 

Orifice

5/64"

3/32"

3/32"

3/32"

 

Minimum operating pressure

2

2

2

2

 

Maximum operating pressure

20

20

20

20

 

Minimum line size

3/8"

3/8"

3/8"

3/8"

 

 

 

 

 

 

 

Maximum fuel flow (CFH)

421

736

736

736

Natural gas

Orifice

9/64"

5/32"

5/32"

5/32"

models

Minimum operating pressure

1

1

1

1

 

Maximum operating pressure

7

7

7

7

 

Minimum line size

1/2"

1/2"

1/2"

1/2"

 

 

 

 

 

 

27

Page 27
Image 27
GSI Outdoors PNEG-377 service manual High Temperature Heater Specifications, Low Temperature Heater Specifications