GSI Outdoors PNEG-377 PRESENTPNEG-286, Flame Detector Kit Installation, Fan and Heater

Models: PNEG-377

1 98
Download 98 pages 21.15 Kb
Page 86
Image 86
1996-PRESENTPNEG-286

FLAME DETECTOR KIT INSTALLATION

Fan and Heater

1996-PRESENTPNEG-286

Flame Detector Kit Installation

Part Number HF-7136

1.Mount the detector module inside the heater control box. Module can be mounted in any position, but install so that moisture cannot get inside unit.

2.Run white wire to common or neutral of 120V power source.

3.Run black wire to terminal that is 110V when heater gets power. (Wire module power in parallel with main solenoid if it is 110V.)

4.Run green and red wires down to sens- ing probe. Red wire should go to flame probe electrode and green wire should go to flame probe ground. For proper operation the ground wire should be connected as close to probe as possible.

5.The remaining three wires are the normally open or normally closed relay contacts that replace the mechanical

flame probe. The blue-black wire is the common, the white-brown wire is the normally closed, and the white-blue is the normally open. On all Airstream heaters use the blue-black and the white-brown wires. The white-blue wire should be used only on makes of heaters that use a normally open probe.

6.110 volt ignition transformer may be connected to (2) 1/4" male spade con- nectors. This will turn off ignition after flame is established. This step is not required for operation.

7.Mount the sensing probe so the sensing portion will be in the flame at its highest and lowest operating conditions.

8.On the side of the flame detector is a red neon light. This light should be on when flame is being sensed and will go out when flame out condition is detected.

 

V

(NOT USED NORMALLY)

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECT WHERE

 

NORMALLY OPEN

 

 

 

 

WHITE/BLUE

 

 

 

 

 

 

 

 

MECHANICAL PROBE

 

COMMON

 

 

 

 

 

 

 

BLUE/BLACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WIRES WERE CONNECTED

 

NORMALLY CLOSED

 

 

 

WHITE/BROWN

 

 

 

 

TO FLAME SENSOR

ELECTRODE

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

VGROUND

 

 

 

 

 

 

 

GREEN

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

BLACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO 110V POWER

WHITE

 

CONNECT WHERE ONE SIDE OF

IGNITION TRANSFORMER WAS CONNECTED

DO NOT MOVE THIS SIDE OF

IGNITION TRANSFORMER CONNECTION

FLAME

DETECTOR

MODULE

IGNITION

TRANSFORMER

86