HEATER ELECTRICAL INSTALLATION

HEATER ELECTRICAL INSTALLATION

Fan and Heater

 

 

 

Heater Electrical Installation (230V Fans)

THESE INSTRUCTIONS ARE FOR HEATER INSTALLATION ON FAN UNITS WITH 230V MOTORS.

BE SURE POWER IS

DISCONNECTED AND LOCKED OUT BEFORE INSTALLATION! FAILURE TO DO SO MAY CAUSE SERIOUS INJURY OR DEATH.

1.Connect power cord to fan control box.

2.Make field connection of wires in fan box as shown in Figure 2. 110V power supply or .5KVA 460V to 110V transformer must be used to supply power for heater. IM-

PORTANT! HEATER MUST BE INTERLOCKED WITH FAN FOR SAFE OPERATION.

3.Connect deluxe thermostat control (optional) as shown in Figure 2. IMPORTANT! THERMOSTAT MUST BE INSTALLED FOR SAFE OPERATION.

Figure 1: Illustration of deluxe vane axial heater wiring installation

on a fan unit.

Figure 2: Deluxe vane axial heater wiring to fan unit.