GSI Outdoors PNEG-377 2ND HEATER INSTALLATION, Installation Standard Units, Fan And Heater

Models: PNEG-377

1 98
Download 98 pages 21.15 Kb
Page 71
Image 71
Manual background

Fan And Heater

2ND HEATER INSTALLATION

For Units using HF-7100 Control Board

2nd Heater Control is Available with the HF-7100 heater control board. For Standard units (1) TD- 100282 Relay must be installed. For HI-LO units (2) TD-100282 Relay and (1) TD-100283 Relay base must be installed. INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRI- CIAN. When points are called out in instructions they are in reference to points on drawing below text.

Installation (Standard Units)

1.Plug (1) TD-100282 Relay into empty socket on HF-7100 Control Board in Main Heater.

2.Run (2) wires from main heater (heater that thermostat is connected to) to 2nd heater.

3.Connect 2 wires to terminals 1 and 2 (Points C and D) of 2nd heater control terminal strip in Main heater.

4.Connect other end of these wires to termi- nals 4 and 5 (Points F and E) on lower left hand corner of HF-7100 board in 2nd heater.

Installation (HI-LO Units)

1.Plug (1) TD-100282 Relay into empty socket on HF-7100 Control board in Main heater.

2.Install TD-100283 Relay base in main heater.

3.Run 1 wire from CYCLE (Point A ) to terminal 13 on Relay Base. Run 1 wire from COMM (Point B) to terminal 14 on relay base.

4.Run (4) wires from Main Heater (Heater that thermostat is connected to) to 2nd Heater.

5.Connect 2 of the wires to terminals 9 and

5 of TD-100283 Relay base in main heater.

 

 

B

A

6.

 

 

 

 

7.

 

 

 

 

8.

H G

F E

D C

 

9.

Connect other end of

these wires to terminals 2 and 3 (Points G and H) on lower left hand corner of HF-7100 board in 2nd heater.

Connect other 2 wires to terminals 1 and 2 (Points D and

C)of 2nd heater control termi nal strip in Main heater.

Connect other end of these wires to terminals 4 and 5 (Points E and F) on lower left hand corner of HF-7100 board in 2nd heater.

Install TD-100282 Relay into TD-100283 Relay base in main heater.

71

Page 71
Image 71
GSI Outdoors PNEG-377 2ND HEATER INSTALLATION, Installation Standard Units, Installation HI-LOUnits, Fan And Heater