GSI Outdoors PNEG-377 service manual Adjusting the Air Pressure Switch, Fan and Heater

Models: PNEG-377

1 98
Download 98 pages 21.15 Kb
Page 41
Image 41
AIR PRESSURE SWITCH

Fan and Heater

AIR PRESSURE SWITCH

 

 

Adjusting the Air Pressure Switch

1.Air pressure switch must be adjusted so that it will activate with lowest level of grain that will be dryed in bin.

2.Put grain in bin to level desired (low).

3.With heater on and fan off display on heater should read "no airflow".

4.Start fan. Heater display should now read

"airflow".

5.If display does not read "airflow" remove cap from adjustment port and slowly turn screw counter clockwise until display does read "Airflow". Figure C

6.Shut fan off display should read "no air flow" when fan gets to half speed. If not repeat step 5.

Figure C

41