Fan and Heater

2ND HEATER INSTALLATION

For Units using HF-7062 Control Board

2nd Heater Control is Available with the HF-7062 heater control board. For Standard units (1) TD- 100282 Relay must be installed. For HI-LO units (2) TD-100282 Relay must be installed. INSTAL- LATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN. When points are called out in instructions they are in reference to points on drawing below text.

Installation (Standard Units)

1.Plug TD-100282 Relay into left 1 pole relay socket on HF-7062 Control Board (This is the socket closest to the 2PDT relay on board See Drawing point I

2.Run (2) wires from main heater (heater that TD-1000282 Relay was installed in) to 2nd heater.

3.Connect wires to terminals 3 and 4 (Points A and B) of 2nd heater control terminal strip in Main heater.

4.Connect wires to terminals 4 and 5 (points E and F) on lower left hand corner of HF-7062 board in 2nd heater or install 2 prong plug on wires and plug into front of control box in receptacle marked CYCLE.

Installation (HI-LO Units)

1.Plug (2) TD-100282 Relay into empty sockets on HF-7062 Control board in Main Heater.

2.Run (4) wires from Main Heater (Heater that TD-100282 Relay were installed in) to 2nd Heater.

3.Connect 2 of the wires to terminals 1 and 2 (Points C and D) of 2nd Heater control terminal strip in main heater.

4.Connect other end of these wires to termi- nals 2 and 3 (Points G and H) on lower left hand corner of HF-7062 board in 2nd heater or install 2 prong plug on wires and plug into front of control box in receptacle marked CYCLE.

5.Connect other 2 wires to terminals 3 and 4 (Points A and B) of 2nd heater control terminal strip in Main heater.

6.Connect other end of these wires to termi- nals 4 and 5 (Points F and G) on lower left hand corner of HF-7062 board in 2nd heater or install 2 prong plug on wires and plug into front of control box in receptacle marked HI-LIMIT.