GSI Outdoors PNEG-377 Chi-Townheater Specifications, Fan and Heater, Med Temperature

Models: PNEG-377

1 98
Download 98 pages 21.15 Kb
Page 32
Image 32
MED TEMPERATURE

CHI-TOWN HEATER SPECIFICATIONS

 

Fan and Heater

 

 

 

 

 

 

 

 

 

 

 

 

 

Btu's Per Gauge Pressure (Psi) Natural Gas Models (Approximate)

 

MED TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diameter

 

 

 

 

Operating Pressure (PSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

26"

 

382,000

 

541,000

662,000

763,000

854,000

936,000

1,011,000

1,083,000

 

 

 

 

 

 

 

 

 

 

 

LOW TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diameter

 

 

 

 

 

Operating Pressure (PSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

26"

 

158,000

 

225,000

275,000

317,000

354,000

388,000

420,000

449,000

 

 

 

 

 

 

 

 

 

 

 

 

 

Gauge Pressure (Psi) Required To Maintain Temperature (Approximate)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Static

 

 

 

Heat Rise Degrees F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Model

Pressure

20

30

40

50

60

70

80

 

 

 

 

 

 

 

 

 

 

 

 

 

2"

 

1

1

2

3

4

5

7

10HP

3"

 

1

1

2

3

4

5

6

4"

 

1

1

2

2

3

4

6

 

 

 

 

 

5"

 

1

1

2

2

3

4

5

 

 

2"

 

1

2

3

4

6

8

 

15HP

3"

 

1

2

3

4

6

7

 

4"

 

1

2

2

4

5

7

8

 

 

 

 

 

5"

 

1

1

2

3

4

5

7

 

 

 

 

 

 

 

 

 

 

 

 

 

3"

 

1

2

4

6

8

 

 

20HP

4"

 

1

2

4

5

8

 

 

5"

 

1

2

3

5

7

 

 

 

 

 

 

 

 

 

6"

 

1

2

3

5

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3"

 

2

3

6

8

 

 

 

25HP

4"

 

2

3

5

8

 

 

 

5"

 

2

3

5

7

 

 

 

 

 

 

 

 

 

 

 

6"

 

1

3

4

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4"

 

2

4

7

 

 

 

 

30HP

6"

 

2

3

5

8

 

 

 

8"

 

2

3

5

7

 

 

 

 

 

 

 

 

 

 

 

10"

 

1

2

3

5

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4"

 

3

6

8

 

 

 

 

40HP

6"

 

2

5

8

 

 

 

 

8"

 

2

4

7

 

 

 

 

 

 

 

 

 

 

 

 

 

10"

 

2

3

5

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32