OPERATING PROCEDURE

Fan and Heater

 

 

Adjusting the vaporizer coil on a liquid propane model. The top photo shows

the setting in, and the bottom photo shows the coil out.

Adjusting The Vaporizor

1.Vaporizer should be adjusted so the vapor pipetrain runs warm to the touch (100°-120°F).

2.Loosen 5/16" bolt on adjust- ment bracket.

3.Swivel vaporizer away from flame if running too hot, closer to flame if too cold.

4.Move vaporizer only 1" at a time and allow a few minutes for tem perature to equalize.

5.Tighten 5/16" bolt and watch heater run for several minutes to verify adjustment.

Running The Dryer

The display will indicate "FLAME" when flame is sensed. If no flame is sensed, the "FLAME" message will be off. The display indicates what part of the cycle it is in. If the unit is a hi-lo dryer, the display will indicate whether it is in the "HI- FLAME" or "LO-FLAME" part of the cycle. (See "programming set points" page 21 for setting the hi-lo flame temperature). If the tempera- ture is above the high temperature set- ting,theflamewillbeoff,the"FLAME" message will be out and the display will be flashing "OFF-CYCLE".

If the flame is shut off because of the humidity sensor (humidistat), the display flashes "OFF-CYCLE HUMIDISTAT".

42

Page 42
Image 42
GSI Outdoors PNEG-377 service manual Adjusting The Vaporizor, Running The Dryer