Fan and Heater

TRANSITION HI-LIMIT INSTALLATION

 

 

Plenum Thermostat

Mounting

The plenum thermostat is the 4 x 4 white box with knob that is preconnected to heater when heater is ordered with thermostat.

1.24" to the right side of the

transition, drill one 3/8" hole (high temp) or 1 1/2" hole (low temp) in the center of the ple- num in a valley (4.00" corru- gation) or hill (2.66" corruga- tion) on bin sidewall.

2.Insert the probe through the hole.

3.Position the housing so that the tabs are vertical, and the cord exits the housing hori- zontally.

Plenum thermostat mounting on bin wall.

4. Use 4 self drilling screws to

5. Caulk between the housing

mount the housing to the bin

and the sidewall to seal.

sidewall.

 

1.Mark location on transition one (1) foot up from the bot- tom (entrance collar) and cen- tered in the transition.

2.Drill or knock out 7/8" diam- eter hole on marked location.

3.Install transition hi-limit us- ing supplied self drilling screws.

Transition Hi-Limit Installation

Figure 2: The transition connecting the Vane Axial Heater to the bin with

the plenum sensor in place.