FAN TROUBLESHOOTING

FAN TROUBLESHOOTING

Fan and Heater

Fan Troubleshooting Chart

SYMPTOM

POSSIBLE CAUSE

Fan will not run

Blown fuse or breaker in disconnect switch

 

Main power not turned on

 

Defective wiring or loose connection

 

Incorrect wire size

 

Overload kicked out

 

Defective motor

 

Defective magnetic contactor

Fan runs for a short period

Undersize wiring

of time then shuts off

 

 

Low line voltage at the installation. Power

 

failure.

 

Magnetic contactor malfunctioning.

 

Defective start/stop button

 

Wrong heater strip

Fan makes ticking noise

Fan blade hitting fan housing

Motor bearing bad

Fan vibratesFan not mounted securely to pad. Fan not level

Fan has dirt deposit on blade

Motor shaft is bent

Blade not mounted properly on shaft

Blade out of balance

SOLUTION

Replace fuses or reset breakers

Turn power on at all disconnects

ahead of the unit

Follow wiring diagram and tighten

any loose connections

See wire size charts for proper sire

size and change if needed

Check manual reset, push in to reset

Replace motor

Check the magnetic contactor

Check to see that power supply wires are the proper size, contact your local power company.

Call power company after making

sure wire size is correct

Change magnetic contactor

Replace necessary part

Replace with proper heater strip

Stop fan and turn off electricity.

Remove fan screen and check to see

if fan blade is hitting the housing.

Adjust motor position to obtain proper

clearance.

Replace motor bearing

Mount fan securely

Level fan

Clean blade

Replace motor

Mount blade properly on shaft

Replace or have blade rebalanced

12