View MR Speed Average

On this screen is information showing you how much time the metering roll system has spent on HI speed and LOW speed. The ideal values of course is at 50% each, although in real world situations this is very difficult to obtain. Having a 30% - 70% reading is not uncommon but anything over this may indicate that meter roll speed settings may need adjusting. This can vary throughout the day due to a number of condi- tions including drying wetter grain or ambient temperature changes of 108 or more.

Reset MR Average

 

Press the

button and move the pointer to change your selection to Reset MR Average

and press the

button.

You can reset the speed average by pressing the

button or you can exit out of this function by

pressing the

button and goto the User Hour Meter screens.

User Hour Meter

The User Hour Meter is a custom timer which can be used for several different scenarios. For instance, if you wanted to monitor the amount of time used between different hybrids of corn or if you have more then one user of the dryer.

Press the

button to exit back to the main drying screen.

Reset User Hour Meter

Pressing the

button at this point will cause the to be reset back to 0.

If this is not the desire action then press the

button to exit back to the main drying screen.

PNEG-951

25

Page 25
Image 25
GSI Outdoors PNEG-951 manual User Hour Meter