During operation the remaining time on each timer is displayed on the screen. If the power goes out or if the dryer is stopped, these times are saved by the controller. When the dryer is restarted the timers will continue timing down. The timers will return to their initial setting if the reset button is pushed.

Use the dryer charts in the back of this manual for reference of a suggested timer settings.

Dry Timer

This timer controls how long the burner will operate. If the moisture control switch is turned on and the dry time reaches zero, then the burner will continue to burn as long as the grain temperature has not reached the moisture control set point.

To change the setting of this timer follow these instructions:

Press the

timer button, press the

button to edit the amount of dry time.

Press the

button to adjust the dry timer settings.

Press the

button to accept the new setting.

During dryer operation the remaining time on each timer is displayed on the screen unless reset to their

stored values by pressing the

button.

Cool Timer

This timer controls how long the fan will operate after the dry timer has expired.

To change the setting of this timer follow these instructions:

Press the

timer button, press the

button to edit the amount of cool time.

Press the

button to adjust the settings.

Press the

button to accept the new setting.

During dryer operation the remaining time on each timer is displayed on the screen unless reset to their

stored values by pressing the

button.

46

PNEG-951

Page 46
Image 46
GSI Outdoors PNEG-951 manual Dry Timer