High End Systems Technobeam 12Replacing the Lamp, Removing the lamp assembly from the fixture

Models: Technobeam

1 173
Download 173 pages 53.15 Kb
Page 131
Image 131

(5)Hot lamp may be an explosion hazard. Do not open for 5 minutes after switching off. Wear eye and hand protection when re- lamping.

(6)Never look directly at the lamp while lamp is on.

(7)Disconnect power before re-lamping or servicing.

1.Unplug the fixture from the power source.

2.Fully back out the two lamp assembly screws shown in Figure 6-13.

Figure 6-13. Loosening the lamp assembly screws gives you access to the fixture lamp.

3.Put on your eye and hand protection. Pull the lamp assembly straight out of the back of the fixture as shown in Figure 6-14.

Figure 6-14. Removing the lamp assembly from the fixture.

6-12Replacing the Lamp

Technobeam® User Manual

Page 131
Image 131
High End Systems Technobeam manual 12Replacing the Lamp, Removing the lamp assembly from the fixture