High End Systems Technobeam manual Precautions, Replacing Fuses

Models: Technobeam

1 173
Download 173 pages 53.15 Kb
Page 121
Image 121

Precautions

This section lists precautions you must follow anytime you are servicing the fixture.

WARNINGS Before performing any service or maintenance, make note of the following:

(1)Hot lamp may be an explosion hazard. Do not open for 5 minutes after switching off. Wear eye and hand protection when re- lamping.

(2)Equipment surfaces may reach temperatures up to 70° C (158° F). Allow 5 minutes for cooling before handling.

(3)Disconnect power before re-lamping or servicing.

(4)Replace fuses with the specified type and rating only.

(5)Never look directly at the lamp while lamp is on.

(6)The procedures in this chapter are intended to assist qualified service personnel because Technobeam fixtures are to be serviced by qualified service personnel only.

Replacing Fuses

This section explains how to replace any of the three fuses located on the fixture’s circuit board. Make note of the warnings in the section titled “Precautions” on page 6-2.

Table 6-1. Replacement Fuses

Fuse

Amps

Volts

Fuse Type

 

 

 

 

 

 

 

 

F1

4.0 A

125 V

Fast Blow Only

F2

2.5 A

250 V

Fast Blow Only

F3

6.3A

250 V

Slow Blow Only

Note

All fuses are 5 mm x 20 mm.

 

6-2

Precautions

Technobeam® User Manual

Page 121
Image 121
High End Systems Technobeam manual Precautions, Replacing Fuses