23.Make sure the fixture is oriented directly at the wall, not at an angle. If the fixture is at an angle to the wall, it might be impossible to align the laser properly.

24.Use the <Up> and <Down> arrow keys to navigate to the TILT option.

25.Press <Enter>, then use the <Up> and <Down> arrow keys to adjust the mirror position until the beam is round.

26.Press <Enter> to accept your selection for TILT.

27.If the beam needs further adjustment, use the <Up> and <Down> arrow keys to navigate to the PAN option.

28.Press <Enter>, then use the <Up> and <Down> arrow keys to adjust the mirror position.

29.Press <Enter> to accept your selection for PAN.

30.Continue adjusting the mirror using PAN and TILT until the beam is as round as possible.

If you cannot see the beam at all, the lamp might be off. Select LAMP from the Test menu and make sure a value of ON is displayed; see Step 5 through Step 8. (If the lamp still does not come on, wait a few minutes and try again.)

31.Use the <Up> and <Down> arrow keys to navigate to the FCUS option.

32.Press <Enter>, then use the <Up> and <Down> arrow keys to focus on the edge of the beam until it is sharp.

33.Continue moving the fixture and focusing on the edge of the beam until the beam is as round as possible, and sharply in focus.

34.When you have focused the beam, press <Enter>.