6.Locate the two lamp optimization (adjust) screws (see Figure 6-18).

Figure 6-18. Lamp optimization screws.

7.Loosen the two lamp optimization screws.

8.Look at the wall where the beam is projected and use the two optimization screws to adjust the lamp’s position within the fixture.

9.When the beam is at its maximum brightness and the light level is even across the beam (or the “hot spot” of brightness is at the center of the beam), retighten the two optimization screws to secure the lamp in its new position.

Resetting Lamp Hours

After changing a lamp, you should reset the number of lamp hours to zero by selecting L/RS from the Info menu. See the menu system help card inside the back cover of this manual, or consult Chapter 3 if you need additional help using the menu system.

Cleaning the Internal Components

Before continuing, read the cautions and warnings in the section titled “Precautions” on page 6-2.

You will need:

- a soft, lint-free cotton cloth

 

- mild glass cleaning solution

 

- warm soapy water