45. Press <Enter>, then use the <Up> and <Down> arrow keys to navigate to the MACR option.
46. Press <Enter>, then use the <Up> and <Down> arrow keys to select LRON (laser on continuously).
47.Press <Enter> to accept your selection.
48.Look at the wall where the beam is projected onto to determine if the laser is on.
49.If the laser does not come on, see the section titled “Troubleshooting” on page
50.Figure
2
1 3
Mounting/alignment screws
Figure 6-27. The laser aiming device assembly has three screws that can be used to adjust the position of the laser.
Alignment screws 1 and 3 (shown in Figure
51.After you tighten/loosen each screw, release pressure from the screwdriver before looking at the laser position on the wall; having pressure on the screw can change the laser’s position. Do not force the screws or fully tighten them because the ends of the screws might interfere with the dim flags.
Hint | If you have difficulty aligning the laser or turning the |
| screws, loosen all three screws and start over. |
52.Continue repeating the procedure until the laser is aligned. (If you cannot get your laser exactly at position shown in Figure
53.When you’re finished, replace the access door shown in Figure
Technobeam® User Manual | Technobeam Laser Aiming Device™ |