Lamp (arrow points

Aperture (arrow

points toward)

away from)

 

One of the following will be printed on each lens:

F

 

W

Front lens, factory-installed lens set

R

 

W

Rear lens, factory-installed lens set

 

F

 

N

Front lens, optional narrow angle lens set

 

R

 

N

Rear lens, optional narrow angle lens set

 

Table 1-2. Beam Angles for Factory-Installed 11 to 17 Degree Lens Set

Beam Angle

Front Lens

Position*

 

 

 

 

 

11.5°

10

 

 

13.5°

8

 

 

15°

6

 

 

16.5°

4

 

 

17.5°

3

 

 

* - For the 11 to 17 degree lens set, the rear lenses must always be placed in slot 1 (see Figure 1-8 on page 1-13).

Table 1-3. Beam Angles for Optional 8 to 12 Degree Narrow Angle Lens Set

Beam Angle

Rear Lens

Front Lens

Position

Position

 

 

 

 

 

 

 

1

10

8.6°

2

10

9.1°

2

9

9.7°

2

8

10.3°

3

8

10.8°

3

7

11.4°

3

6

12°

3

5

7.When you are finished, replace the lens tube cover, making sure to point the arrow on the cover toward the front of the fixture.

1-14Setting the Beam Angle

Technobeam® User Manual

Page 41
Image 41
High End Systems Technobeam manual 14Setting the Beam Angle, Away from