Table 3-1. Technobeam Menu Map

Menu

Menu

Menu

Menu

Menu

Description

Level 1

Level 2

Level 3

Level 4

Level 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPEN

fully open the iris

 

 

 

 

P 01 -

select a speed to strobe the beam diameter,

 

 

 

 

P 16

from slow (P 01) to fast (P 16)

 

 

 

 

N 01 -

select a random frequency to strobe the beam

 

 

 

 

diameter, from less often (N 01) to more often

 

 

 

 

N 16

 

 

 

 

(N 16)

 

 

 

 

 

 

 

 

 

RS01 -

select the speed to ramp open, slow (RS01) to

 

 

 

 

RS16

fast (RS16), then snap shut

 

 

 

 

SR01 -

select the speed to snap open, then ramp shut

 

 

 

 

SR16

slow (SR01) to fast (SR16)

 

 

 

IRIS

RR01 -

select the speed to ramp open, then ramp shut

 

 

 

 

RR16

slow (RR01) to fast (FF16)

 

 

 

 

NR01 -

select the random frequency to ramp open,

 

 

 

 

from less often (NS01) to more often (NS16),

 

 

 

 

NR16

 

 

 

 

then snap shut

 

 

 

 

 

 

 

 

 

NS01 -

select the random frequency to snap open,

 

 

 

 

then ramp shut from less often (NR01) to more

 

 

 

 

NS16

 

 

 

 

often (NS16)

 

 

 

 

 

 

 

 

 

CLSD

close the iris

 

 

 

 

I001 -

select a beam diameter, from small (I001) to

 

 

 

 

I127

large (I127)

 

 

 

MSPD

0.15 -

select an MSpeed value in decimal seconds

 

 

 

252.7

from fast (0.15) to slow (252.7)

 

 

 

 

 

 

SN01-

 

X 0.1 -

select the DIM and FCUS construct’s

PRST

EDIT

 

X 9.9

crossfade time in increments of 0.1

SN16

XFAD

 

 

X 10 -

select the DIM and FCUS construct’s

 

 

 

 

 

 

 

 

X166

crossfade time in increments of 1

 

 

 

 

D 0.1 -

select the delay time in increments of 0.1

 

 

 

 

D 9.9

 

 

 

DLAY

 

 

 

 

D 10 -

select the delay time in increments of 1

 

 

 

 

 

 

 

 

D166

 

 

 

 

 

 

 

 

 

MCOF

set macro OFF

 

 

 

 

MC01 -

select a factory-programmed macro from 1 - 28

 

 

 

 

MC28

 

 

 

 

 

 

 

 

 

LROF

set Laser Aiming Device (LAD™) OFF¹

 

 

 

MACR

LRON

set Laser Aiming Device (LAD™) ON

 

 

 

 

continuously¹

 

 

 

 

 

 

 

 

 

LM01 -

select a LAD™ strobe speed from slow (4.25

 

 

 

 

per second - LM01) to fast (255 per second -

 

 

 

 

LM30

 

 

 

 

LM30)¹

 

 

 

 

 

 

 

 

 

SEC

select seconds as the units of time used for the

 

 

 

 

XFAD and DLAY constructs

 

 

 

 

 

 

 

 

TIME

MIN

select minutes as the units of time used for the

 

 

 

XFAD and DLAY constructs

 

 

 

 

 

 

 

 

 

HOUR

select hours as the units of time used for the

 

 

 

 

XFAD and DLAY constructs

 

 

 

 

 

 

 

 

 

 

erase any programming of the current scene

 

 

 

ZERO

OK

by voiding all construct values / mark the end

 

 

 

 

 

of a loop

Technobeam® User Manual