2.Press the <Enter> button to enter the “ADDR” menu.

3.Using the <Up> and <Down> arrow buttons, scroll to the desired DMX

t

start channel and press the <Enter> button to select the desired DMX

start channel.

 

 

Note

You must assign a unique fixture address to each Studio

 

 

Spot 250 or Studio Color 250 fixture that you wish to

 

 

respond independently to controller commands.

Determining the Unique Fixture Number

The fixture number is a number you assign that represents each unique fixture’s channel range in the DMX 512 link. If you are using one DMX link to control fixtures which all use the same number of DMX channels (as recommended), you can assign fixture numbers in ascending order (see Table 2-3).

Table 2-3. Example: Determining the Unique Fixture Number

Fixture

 

Number of DMX

Fixture

Channel

location

Fixture name

channels used

number

range used

on the link

 

per fixture

 

 

 

 

 

 

 

 

 

 

 

 

 

First

Technobeam

18 channels

F 01

1-18

(iris protocol)

 

 

 

 

Second

Technobeam

18 channels

F 02

19-36

(iris protocol)

 

 

 

 

Third

Technobeam

18 channels

F 03

37-54

(full protocol)

 

 

 

 

Fourth

Other device

18 channels

F 04

55-72

(using 18 channels)

 

 

 

 

t

To assign a unique fixture number to your fixture:

1. Press and hold the <Menu> button until “ADDR” appears on the LED display.

2.Press the <Enter> button to enter the “ADDR” menu.

3. Using the <Up> and <Down> arrow buttons, scroll to the desired fixture number and press the <Enter> button.

Note

You must assign a unique fixture address to each

 

Technobeam fixture that you wish to respond

 

independently to controller commands.

Wasted DMX Channels

If you mix different types of devices (which use different numbers of channel ranges) on the same DMX link and assign fixture numbers (instead of DMX start channels) to these devices, you would waste DMX channels.