Table 6-2 describes the typical failure symptoms of each of the fuses:

 

 

Table 6-2. Fuse Failure Symptoms

 

 

 

Fuse

Protects

Symptoms of Failure

 

 

 

 

 

 

F1

Motor power

Motor LED is OFF when fixture is receiving power. Receive LED

 

 

might be ON. Motors and gears will not move, lamp is OFF.

F2

Logic power

Fixture shuts down, LEDs might be ON.

F3

Main fuse

Fixture shuts down, LEDs are all OFF.

1.Unplug the fixture from the power supply.

2.Lay the fixture on its back and locate the door retaining screw, as shown in Figure 6-1:

Door retaining screw

Access door

Figure 6-1. Removing the door allows you to access the fixture’s voltage selection switches and fuses, as well as wheels and optics.

3.Note which fuse(s) needs to be replaced and make sure you replace it with a fuse of the same type and rating, as shown in Table 6-2.

Technobeam® User Manual

Replacing Fuses

6-3