EMEM Ack

This error may occur during data storage when an attempted write has taken too long. Attempt the operation again. If this message reoccurs, contact High End Systems Customer Service in one of the ways shown in the section titled “Contacting High End Systems” on page Intro-4.

EMEM [message]

(Memory error.) This error indicates the fixture was unable to retrieve one of the following from non-volatile storage:

CHNL—the fixture’s DMX start channel.

DPLY—LED display status (on, off, dim).

FHRS—number of fixture operating hours.

LENS—lens set selection (NORM for factory-installed or optional narrow angle set, WIDE for optional wide angle lens set).

LHRS—number of lamp operating hours.

L/ST—lamp strikes.

MODE—preset playback status (ON/OFF/SCN).

PERS—the fixture’s protocol (e.g., Technobeam full protocol).

PINV—pan invert status.

TINV—tilt invert status.

S/DN—shutdown time.

SWAP—pan/tilt swap status.

TIMB—time base (seconds, minutes, hours) for preset playback.

The most likely cause is that an electrical event occurred and either interrupted data storage or caused the non-volatile memory to be corrupted. Try restoring the lost items manually. If the problem persists, contact High End Systems Customer Service in one of the ways shown in the section titled “Contacting High End Systems” on page Intro-4.

Erse Flsh

Occurs during a crossload when the time required to erase a fixture’s memory is excessive. Remove the fixture from the link and contact High End Systems Customer Service. You might need to restart the crossload as well.

ID Lost

The system software was unable to read the fixture’s ID number (fixture number or DMX start channel) from its non-volatile storage area. Try unplugging the fixture, waiting a short time, then plugging it back in. If this error message reoccurs, contact High End Systems Customer Service in one of the ways shown in the section titled “Contacting High End Systems” on page Intro-4.

2-26Troubleshooting

Technobeam® User Manual

Page 67
Image 67