Table A-1. Technobeam DMX Protocol
Ch. (F) | Ch. (R) | Construct | Parameter | Value | Value | Value | ||
(dec.) |
| (%) | (hex) | |||||
|
|
|
|
| ||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
| Random | Random pause time, | 0 - 255 | 0 - 100 | 00h | - FFh | |
|
|
| shortest to longest |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| Scan | Scan rate, slowest to | 0 - 255 | 0 - 100 | 00h | - FFh | |
|
|
| fastest |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| Litho wheel spin (use with ch. 7 | Forward spin, fastest to | 0 - 119 | 0 - 47 | 0 - 77h | ||
|
| (F) or ch. 5 (R) | slowest |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Entire wheel spins, not | No spin | 120 - 135 | 47 | - 53 | 78h | - 87h |
|
|
|
|
|
|
|
| |
|
| individual lithos |
|
|
|
|
|
|
|
|
| Reverse spin, slowest | 136 - 255 | 53 | - 100 | 88h | - FFh |
|
|
| to fastest |
|
|
|
|
|
|
|
|
|
|
|
|
| |
10 | n/a | Litho rotation (fine | Angular position for | 0 - 255 | 0 - 100 | 00h | - FFh | |
|
| adjustment) | blink and index modes |
|
|
|
|
|
|
|
|
|
|
|
|
| |
11 | 8 | Effects position | Position 1 | 0 - 25 | 0 - 9 | 00h | - 19h | |
|
|
|
|
|
|
|
| |
|
| Fast effects changes (at | Position 2 | 26 - 51 | 10 | - 20 | 1Ah - 33h | |
|
|
|
|
|
|
|
| |
|
| beginning of wheel movement) | Position 3 | 52 - 76 | 21 | - 29 | 34h | - 4Ch |
|
|
| ||||||
|
| Select the position with this |
|
|
|
|
|
|
|
| Position 4 | 77 - 102 | 31 | - 40 | 4Dh - 66h | ||
|
| channel. Then use ch. 12 (F) or | ||||||
|
|
|
|
|
|
|
| |
|
| Position 5 | 103 - 127 | 41 | - 49 | 67h | - 7Fh | |
|
| ch. 9 (R) to set spin direction | ||||||
|
| and speed. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Effects changes set by MSpeed | Position 1 | 128 - 153 | 50 | - 60 | 80h | - 99h |
|
| (use ch. 16 (F) or 13 (R) to set |
|
|
|
|
|
|
|
| Position 2 | 154 - 178 | 61 | - 69 | 9Ah - B2h | ||
|
| MSpeed time) | ||||||
|
|
|
|
|
|
|
| |
|
| Select the position with this | Position 3 | 179 - 204 | 70 | - 80 | B2h - CCh | |
|
|
|
|
|
|
|
| |
|
| channel. Then use ch. 12 (F) or | Position 4 | 205 - 229 | 81 | - 89 | CDh - E5h | |
|
| ch. 9 (R) to set spin direction | ||||||
|
|
|
|
|
|
|
| |
|
| Position 5 | 230 - 255 | 90 | - 100 | E6h - FFh | ||
|
| and speed | ||||||
|
|
|
|
|
|
|
| |
12 | 9 | Effects spin speed | Forward spin fast to | 0 - 120 | 0 - 47 | 00h | - 78h | |
|
|
| slow forward spin |
|
|
|
|
|
|
| (use with ch. 11 (F) or |
|
|
|
|
|
|
|
| No spin | 121 - 134 | 48 | - 52 | 79h | - 86h | |
|
| ch. 8 (R)) | ||||||
|
|
|
|
|
|
|
| |
|
|
| Reverse spin slow to | 135 - 255 | 53 | - 100 | 87h | - FFh |
|
|
| fast forward spin |
|
|
|
|
|
|
|
|
|
|
|
|
| |
13 | 10 | Focus | Variable focus | 0 - 255 | 0 - 100 | 00h | - FFh | |
|
|
|
|
|
|
|
| |
14 | 11 | Shutter | Closed | 0 - 7 | 0 - 2 | 00h | - 07h | |
|
|
|
|
|
|
|
| |
|
|
| Periodic strobe | 8 - 67 | 3 - 26 | 08h | - 43h | |
|
|
|
|
|
|
|
|
|
|
|
| Random strobe | 68 - 127 | 27 | - 49 | 44h | - 7Fh |
|
| Longest ramp time = lowest |
|
|
|
|
|
|
|
| Ramp open, snap shut | 128 - 187 | 50 | - 73 | 80h | - BBh | |
|
| value (snap time is always | ||||||
|
|
|
|
|
|
|
| |
|
| Snap open, ramp shut | 188 - 247 | 74 | - 96 | BCh - F7h | ||
|
| short) | ||||||
|
|
|
|
|
|
|
| |
|
|
| Open | 248 - 255 | 97 | - 100 | F8h - FFh | |
|
|
|
|
|
|
|
| |
15 | 12 | Dim | Full dark to full bright | 0 - 255 | 0 - 100 | 00h | - FFh | |
|
|
|
|
|
|
|
| |
16 | 13 | MSpeed | Movement time (see Table |
|
| |||
|
|
|
|
|
|
|
|
|
| Technobeam® User Manual |