Environmental Specifications

Maximum ambient temperature (Ta):

50° C (122° F)

Maximum exterior surface temperature:

70° C (158° F)

Minimum distance to flammable objects:

1.0 m (3.28 ft)

Minimum distance to lighted object:

1.0 m (3.28 ft)

DMX Data Cabling

DMX data cables: Belden® 9841 or equivalent (meets specifications for EIA RS-485 applications) with characteristics listed below:

2-conductor, twisted pair plus a shield

maximum capacitance between conductors - 30 pF/ft.

maximum capacitance between conductor & shield - 55 pF/ft.

maximum resistance of 20 Ω /1000 ft.

nominal impedance 100–140

22–24 AWG with insulation having a dielectric rating of 300 volts or higher

DMX data connectors: 3-pin male and female XLR connectors

DMX data terminators: Male XLR connector with 120 ohm terminator between pins 2 and 3 (see Figure 2-4 on page 2-6)

Controllers

Technobeam may be controlled with any of the following:

The Status Cue® lighting system

The Technobeam LCD controller

Another DMX 512-compatible controller

Optional Accessories

Table 1-1 below shows the optional accessories for Technobeam, available from your High End Systems® dealer/distributor:

Table 1-1. Optional Accessories

Name

Part Number

 

 

 

 

Optional lens sets

Call*

Replacement MSD 250-2 lamp

Call*

Custom color wheel dichroic filters

Call*

LithoPatterns

Call*