41PNEG-951
Plenum Temperature Setpoint
The plenum temperature set point will determine the average temperature of air entering the grain columns.
To change the burner cycling mode, please refer to Fan/Heater Select topic section of the Initial Setup
Parameters chapter.
To change the setting of the plenum temperature follow these instructions:
1.Press thetemps button.
2.Pressto advance to the next plenum screen orto change the set point.
3.Press thebutton to adjust the settings.
4.Press thebutton to accept the changes.
STARTUP

Startup Procedure

At the beginning of each harvest and before filling the dryer with grain make sure to inspect the dryer for
rodent damage, proper belt and chain tension and missing or damaged safety shields. Test operate the dryer
using the pre start check procedures.
1.Before attempting to operate the dryer make sure that all safety shields are in place, all plenum bottom
closure panel doors are closed, all rear access doors are closed and all personnel are clear of the grain dryer
and grain handling machinery.
2.Turn all selector switches on the control panel to the off position.
3.Turn on the electrical power supply to the dryer, and move the safety disconnect handle mounted on the
dryers upper power box to on.
4.Turn the control power switch to on. The switch will light up. A copyright message, model number, total
running time in hours and minutes, current date and time will appear. At this point the controller will lock out all
other dryer functions. Once the time and date screen appears, press thebutton and the dryer will
perform its safety circuit checks. If a fault is found the cause will be displayed on the LCD. If all safeties do not
detect a problem the controller will allow the electronic fuel shutoff valve (Maxon) to be manually opened, if so
equipped, and the drying mode switch will light up, indicating that the dryer is ready to be started.
5.Move the load auger switch to manual, and push the dryer power start switch. The top auger will immedi-