RS-232C Communication (continued)

Names

 

Operation Type

 

 

Header

 

 

 

 

 

 

 

Command Data

 

 

 

 

 

 

CRC

 

Action

 

Type

 

Setting Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

Set

Turn off

BE EF

03

 

06

00

 

2A

D3

 

01

00

 

00

60

 

00

00

 

 

Turn on

BE EF

03

 

06

00

 

BA D2

 

01

00

 

00

60

 

01

00

 

 

Get

BE EF

03

 

06

00

 

19 D3

 

02

00

 

00

60

 

00

00

 

 

 

(Example

return)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00 00

 

 

01 00

 

 

02

00

 

 

 

 

 

 

 

 

 

 

(Off)

 

 

(On)

 

 

 

(Cool down)

 

 

 

 

 

RGB2 Status

 

Get

BE EF

03

 

06

00

 

F1 D8

 

02

00

 

21

20

 

00

00

 

 

 

 

00 00

 

 

01 00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(RGB IN2)

 

(RGB OUT)

 

 

 

 

 

 

 

 

 

 

Input Source

Set

RGB IN 1

BE EF

03

 

06

00

 

FE D2

 

01

00

 

00

20

 

00

00

 

 

RGB IN 2

BE EF

03

 

06

00

 

3E

D0

 

01

00

 

00

20

 

04

00

 

 

VIDEO

BE EF

03

 

06

00

 

6E

D3

 

01

00

 

00

20

 

01

00

 

 

S-VIDEO

BE EF

03

 

06

00

 

9E

D3

 

01

00

 

00

20

 

02

00

 

 

COMPONENT

BE EF

03

 

06

00

 

AE D1

 

01

00

 

00

20

 

05

00

 

 

Get

BE EF

03

 

06

00

 

CD D2

 

02

00

 

00

20

 

00

00

Error Status

 

Get

BE EF

03

 

06

00

 

D9

D8

 

02

00

 

20

60

 

00

00

 

 

 

(Example

return)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00 00

 

 

01 00

 

 

02

00

 

 

 

03 00

 

 

 

 

(Normal)

 

(Cover error)

 

 

(Fan error)

 

(Lamp error)

 

 

 

 

 

04 00

 

 

05 00

 

 

06

00

 

 

 

07 00

 

 

 

 

(Temp error)

 

(Air flow error)

(Lamp time error)

 

(Cool error)

 

 

 

 

 

08 00

 

 

09 00

 

 

10 00

 

 

 

 

 

 

 

 

 

(Filter error)

 

(Filter missing error)(Inner Sencer error)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BRIGHTNESS

 

Get

BE EF

03

 

06

00

 

89 D2

 

02

00

 

03

20

 

00 00

 

 

Increment

BE EF

03

 

06

00

 

EF D2

 

04

00

 

03

20

 

00

00

 

 

Decrement

BE EF

03

 

06

00

 

3E

D3

 

05

00

 

03 20

 

00

00

BRIGHTNESS Reset

 

Execute

BE EF

03

 

06

00

 

58 D3

 

06

00

 

00

70

 

00

00

CONTRAST

 

Get

BE EF

03

 

06

00

 

FD D3

 

02

00

 

04

20

 

00

00

 

 

Increment

BE EF

03

 

06

00

 

9B

D3

 

04

00

 

04

20

 

00

00

 

 

Decrement

BE EF

03

 

06

00

 

4A

D2

 

05

00

 

04

20

 

00

00

CONTRAST Reset

 

Execute

BE EF

03

 

06

00

 

A4

D2

 

06

00

 

01

70

 

00

00

MODE

Set

NORMAL

BE EF

03

 

06

00

 

23

F6

 

01

00

 

BA 30

 

00 00

 

 

CINEMA

BE EF

03

 

06

00

 

B3 F7

 

01

00

 

BA 30

 

01 00

 

 

DYNAMIC

BE EF

03

 

06

00

 

E3 F4

 

01 00

 

BA 30

 

04 00

 

 

Get

BE EF

03

 

06

00

 

10

F6

 

02

00

 

BA 30

 

00 00

 

 

 

(Example

return)

 

 

 

 

 

 

10 00

 

 

 

 

 

 

 

 

 

 

00

00

 

01 00

04 00

 

 

 

 

 

 

 

 

 

 

 

(Normal)

(Cinema)

(Dynamic)

(Custom)

 

 

 

 

 

GAMMA

Set

#1 DEFAULT

BE EF

03

 

06

00

 

07 E9

 

01

00

 

A1 30

 

20 00

 

 

#1 CUSTOM

BE EF

03

 

06

00

 

07 FD

 

01

00

 

A1 30

 

10

00

 

 

#2 DEFAULT

BE EF

03

 

06

00

 

97 E8

 

01

00

 

A1 30

 

21

00

 

 

#2 CUSTOM

BE EF

03

 

06

00

 

97 FC

 

01

00

 

A1 30

 

11 00

 

 

#3 DEFAULT

BE EF

03

 

06

00

 

67 E8

 

01 00

 

A1 30

 

22

00

 

 

#3 CUSTOM

BE EF

03

 

06

00

 

67 FC

 

01

00

 

A1 30

 

12

00

 

 

Get

BE EF

03

 

06 00

 

F4 F0

 

02

00

 

A1 30

 

00

00

8

Page 101
Image 101