ELECTRICAL CONNECTIONS
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT.
WARNING: APPLIANCES EQUIPPED WITH A FLEXIBLE ELECTRIC SUPPLY CORD ARE PROVIDED WITH A
Access the electrical connection point by removing the side panel(s) where the controls are located. Ensure that the electrical power supply agrees with the specifications on the oven's data plate and complies with the wiring diagram, located behind the oven side panel and under the drive motor.
Stacked Ovens or Oven and Warmer
Refer to the Stacking Kit Installation Instruction
Single Oven or Warmer
1.Remove the side panels.
2.At the same time attach power leads to oven or warmer terminal block as shown on the wiring diagram, located behind the side panel and under the drive motor, and attach the power supply conduit to the bottom of the oven or warmer.
3.Attach power supply leads to line side of the terminal block.
4.Inspect and check all wiring and terminal connections for tightness and proper routing away from any moving parts or pinch points.
5.Carefully replace the side panels.
Refer to the Electrical Data chart on the next page.
– 10 –