Hobart HR5 manual Electrical Data, Volts, Hertz, Phase, Circuit Size, Amps, Stacked Models

Models: HR5

1 36
Download 36 pages 25.73 Kb
Page 11
Image 11
ELECTRICAL DATA

ELECTRICAL DATA

MODEL

VOLTS

HERTZ

PHASE

CIRCUIT SIZE*

 

 

 

 

(AMPS)

 

 

 

 

 

HR5

208

60

1

35

 

208

60

3

20

 

240

60

1

35

 

240

60

3

20

 

 

 

 

 

HR7

208

60

1

60

 

208

60

3

35

 

240

60

1

60

 

240

60

3

35

 

 

 

 

 

HW5

208

60

1

15

 

208

60

3

10

 

240

60

1

15

 

240

60

3

10

 

 

 

 

 

HW7

208

60

1

15

 

208

60

3

15

 

240

60

1

20

 

240

60

3

15

 

 

 

 

 

STACKED MODELS

 

 

 

 

 

 

 

 

 

(2) HR5

208

60

1

70

 

208

60

3

40

 

240

60

1

70

 

240

60

3

45

 

 

 

 

 

(2) HR7

208

60

3

70

 

240

60

3

70

 

 

 

 

 

(2) HW5

208

60

1

30

 

208

60

3

-

 

240

60

1

35

 

240

60

3

-

 

 

 

 

 

(2) HW7

208

60

1

30

 

208

60

3

25

 

240

60

1

40

 

240

60

3

30

 

 

 

 

 

HR5 & HW5

208

60

1

50

 

208

60

3

40

 

240

60

1

50

 

240

60

3

40

 

 

 

 

 

HR7 & HW7

208

60

1

80

 

208

60

3

50

 

240

60

3

80

 

240

60

1

50

 

 

 

 

 

*Maximum Circuit Breaker Size / Minimum Circuit Amperage compiled in accordance with the National Electrical Code, 1990 edition.

– 11 –

Page 11
Image 11
Hobart HR5 manual Electrical Data, Volts, Hertz, Phase, Circuit Size, Amps, Stacked Models