Holder Maintenance Every 1000 Service Hours, Checking Valve Clearance, C 9700 ... C 9.88 H

Models: A4 VG 40 EP A6 VM 55 EP C 9700 C 9700 H C 9.72 C 9.78 H C 9800 H C 9.83 H C 9.72 H C 9.88 H VG 50 EP

1 221
Download 221 pages 26.52 Kb
Page 184
Image 184
Maintenance Every 1000 Service Hours

C 9700 ... C 9.88 H

Operating Instructions

Maintenance Every 1000 Service Hours

Checking Valve Clearance

See the operating manual of the engine manufacturer.

Checking the Battery

CAUTION

For the sake of your safety, observe the fol- lowing instructions.

The battery contains dissolved sulphuric acid, which is poisonous and caustic.

When working with battery acid, wear per- sonal protective equipment (protective apron, protective gloves) and eye protectors. If your clothing, skin or eyes have nevertheless come in contact with battery acid, the affected parts must be rinsed at once with water. If the eyes are affected, seek medical aid im- mediately. Neutralize spilled battery acid im- mediately.

Gases are released when batteries are charged. To prevent an explosion, keep sparks, naked fires away. Rooms, in which batteries are charged or stored, must be ventilated accordingly.

NOTE

The charging, servicing and care of the battery must always be according to the maintenance instructions of the battery manufacturer.