14
7) Startup–"POWER OK" LED is on: Move the power switch to the "ON" position,
then move the control switch to the "ICE" position. CB "POWER OK" LED is on.
"POWEROK" LED Diagnosis:Check that CB "POWER" LED is on. If not, check for
proper power supply voltage (115VAC) input to CT. If 115VAC is not present, check the
breaker, power switch, and safety switch. Next, check that the power protect relay is
de-energized and contacts between terminals #6(BR) and #2(BK) are closed. Check
for proper control voltage (24VAC) output from CT. Next, check the 24VAC 1A fuse. If
open, replace. Check for 24VAC at CB K8connector pin #1 (W/R) to CB K8 connector
pin #2 (LBU). If24VAC is not present at CB K8 connector pin #1 (W/R) but is present at
1A fuse (W/R), check continuity of control switch. If open, replace. If24VAC is present
between CB K8 connector pin #1 (W/R) and pin #2 (LBU), and "POWER OK" LED is
off, replace CB.
BC Diagnosis: Check that the actuator paddle is properly positioned. Check for
continuity across BC proximity switch. When BC proximity switch is closed 0VDC is
read across CB K8 connector pin #3(GY) and #4 (GY). 5VDC is present between CB
K8 connector pin #3 (GY) or #4(GY) to CB red K4 connector pin closest to CB black K3
black connector (5VDC GND). If 5VDC is not present, replace CB.
HPS Diagnosis: HPS automatically resets when refrigeration circuit high-side pressure
is within an acceptable range. 5VDC is supplied from CB K9connector pin #3 (Y) and
back onto CB K9 connector pin #4 (Y). If 5VDC is not present at CB K9 connector pin
#3 (Y) to CB red K4 connector pin closest to CB black K3 connector (5VDC GND)
and CB "POWER OK" LED is on, replace CB. Ifrefrigerant pressures have returned
to an acceptable range and HPS does not close, replace HPS. Ifpressures have not
equalized, and refrigeration circuit high-side pressure does not drop, recover, evacuate,
and recharge if necessary. On air-cooled model, check that the condenser is not dirty
or clogged, check for proper FMoperation and fan blade for binding. On water-cooled
model, check WRV and water ow in and out of condenser. Check for refrigeration
circuit refrigerant restriction (TXVand drier).
8) Fill Cycle–"WTRIN" LED is on: WV energizes. 90-sec. FT starts. LFScloses. Nothing
happens at this time. Reservoir continues to ll. UFS closes, WV de-energizes, 90-sec.
FT terminates. Diagnosis: If the reservoir is empty, LFS open, "WTRIN" LED on, and
WV off, check for 24VAC at CB K2connector pin #8(W/BR) to a neutral(LBU).
If 24VAC is not present, conrm 24VAC power supply at CB K2connector pin #7 (W/R)
to a neutral (LBU). If 24VAC is not present on CB K2connector pin #7 (W/R), check
wiring connections from CT. If24VAC is present on CB K2 connector pin #7 (W/R)
and not on CB K2 connector pin #8 (W/BR), replace CB. If 24VAC is present on CB
K2connector pin #8 (W/BR), check for 24VAC at WV solenoid. If 24VAC is present,
replace WV. If WV is energized and ll/rell exceeds 90-sec. FT with no water in the
reservoir, check for clogged WV screen or DVleaking. Note: IfUFS remains open
90seconds after LFS opens (WV energized), a 1-beep alarm sounds (90 sec. FT). This
alarm resets automatically once UFS closes. If reservoir is full and overowing, check
for open UFS. See "II.E. Float Switch Check and Cleaning." If WV de-energizes and
water continues to ll the reservoir, replace WV.