59
Note:1. The data not in bold should be used for reference only.2. We reserve the right to make changes in specications and design without prior
notice.
APPROXIMATE Ambient
ICE PRODUCTION Temp. (°F)
PER 24 HR. 70 800 363 779 353 758 344
80 738 335 719 326 700 317
90 681 309 685 311 646 293
lb./day kg/day 100 629 285 612 278 563 255
APPROXIMATE ELECTRIC 70 1274 -- 1275 -- 1276 --
CONSUMPTION 80 1277 -- 1278 -- 1279 --
90 1280 -- 1281 -- 1284 --
watts 100 1286 -- 1289 -- 1291 --
APPROXIMATE WATER 70 474 1.79 513 1.94 686 2.60
CONSUMPTION PER 24 HR. 80 504 1.91 565 2.14 804 3.04
90 513 1.94 609 2.31 823 3.11
gal./day l/day 100 623 2.36 659 2.49 1019 3.86
EVAPORATOR OUTLET TEMP. 70 12 -11 12 -11 12 -11
80 12 -11 12 -11 12 -11
90 12 -11 12 -11 13 -10
°F °C 100 13 -10 13 -10 13 -10
HEAD PRESSURE 70 258 18.1 258 18.1 258 18.1
80 259 18.2 259 18.2 259 18.2
90 260 18.3 260 18.3 260 18.3
PSIG kg/cm²G 100 257 18.1 257 18.1 257 18.1
SUCTION PRESSURE 70 32 2.3 32 2. 3 32 2.3
80 33 2.3 33 2.3 33 2.3
90 33 2.3 33 2.3 33 2.3
PSIG kg/cm²G 100 35 2.4 35 2.4 35 2.4
WATER FLOW FOR CONDENSER 20gal/h (AT 90°F /WT 70°F)
PRESSURE DROP OF COOLING WATER LINE Less than 7 PSIG
HEAT OF REJECTION FROM CONDENSER 8,100 BTU/h (AT 90°F /WT 70°F)
HEAT OF REJECTION FROM COMPRESSOR 1,300 BTU/h (AT 90°F /WT 70°F)
HEAT OF REJECTION FROM GEAR MOTOR 700 BTU/h (AT 90°F /WT 70°F)
Water Temp. (°F)
50 70 90
2. DCM-751BWH(-OS)