2. Ice/Water Dispensing
| Ice |
|
|
1. Power Supply | a) Off, blown fuse, or tripped breaker. |
|
|
2. Control Board | a) Ice dispense switch circuit open or no power (5VDC) from control |
| board. |
| b) No power (115VAC) to ice dispense solenoid, ice dispense motor, or |
| agitating motor. |
|
|
3. Ice Dispense Switch | a) Defective. |
|
|
4. Dispense Mode Switch | a) Defective. |
|
|
5. Ice Dispense Motor | a) Motor windings. |
| b) Mechanical failure. |
|
|
6. Ice Dispense Solenoid | a) Defective or loose connection. |
|
|
7. Shutter Assembly | a) Defective. |
|
|
8. Agitating Motor | a) Motor windings. |
| b) Mechanical failure. |
|
|
| Ice |
|
|
1. Power Supply | a) Off, blown fuse, or tripped breaker. |
|
|
2. Control Board | a) No power to dispense mode switch. |
|
|
| b) Dispense mode switch circuit open. |
| c) No power to ice dispense solenoid, ice dispense motor, or agitating |
| motor. |
|
|
3. Infrared Sensor | a) Defective. |
|
|
4. Dispense Mode Switch | a) Defective (open). |
|
|
5. Ice Dispense Motor | a) Motor windings. |
| b) Mechanical failure. |
|
|
6. Ice Dispense Solenoid | a) Defective or loose connection. |
|
|
7. Shutter Assembly | a) Defective. |
|
|
8. Agitating Motor | a) Motor windings. |
| b) Mechanical failure. |
|
|
| Water |
|
|
1. Power Supply | a) Off, blown fuse, or tripped breaker. |
|
|
2. Water Dispense Switch | a) Defective. |
3. Water Dispense Valve | a) Water supply turned off. |
|
|
| b) Defective. |
|
|
| Water |
|
|
1. Power Supply | a) Off, blown fuse, or tripped breaker. |
2. Infrared Sensor | a) Defective. |
|
|
3. Control Board | a) No power to infrared sensor. |
|
|
| b) No power to water dispense valve. |
|
|
4. Water Dispense Valve | a) Water supply turned off. |
| b) Defective. |
|
|
31