4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
The dispense mode switch must be in the "CONTINUOUS" position for this setting to apply. The factory setting allows ice to be dispensed continuously on push button models and for a maximum of 60 sec. on
S1 Dip Switch Setting | Dispense Time | ||
No. 5 | No. 6 | ||
| |||
|
|
| |
OFF | OFF | No Limit | |
|
|
| |
ON | OFF | 20 Seconds | |
OFF | ON | 60 Seconds | |
|
|
| |
ON | ON | No Limit | |
|
|
|
5. Bin Control Selector (S1 dip switch 7)
The appliance is factory set for mechanical bin control operation. No adjustment is required. In the factory default position (S1 dip switch 7 in the off position), the gear motor delay after the upper float switch closes is 5 seconds. WARNING! Do not adjust
S1 dip switch 7 out of the factory default position. This dip switch must be left in the factory default position or the appliance will not operate correctly.
S1 Dip Switch |
|
| |
Setting | Bin Control Application | Gear Motor Delay | |
No. 7 |
|
| |
|
|
| |
OFF | Mechanical Bin Control | 5 seconds | |
|
|
| |
ON | Infrared Sensor with | 30 seconds | |
Mechanical Bin Control Backup | |||
|
|
6. Bin Control Shutdown Delay (S1 dip switch 8)
Factory set for normal operation. No adjustment is required. The shutdown delay is the time between the mechanical bin control proximity switch opening and the control board shutting off the appliance.
S1 Dip Switch | Bin Control #1 | |
Setting | ||
Shutdown Delay | ||
| ||
No. 8 | ||
| ||
|
| |
OFF | 0.25 Seconds | |
ON | 6.7 Seconds |
7. Factory Use (S1 Dip Switch 9 & 10)
Factory set for optimum performance. Do not adjust.