C. Settings and Adjustments

NOTICE

Dip switches are factory set. Failure to maintain factory settings may adversely affect performance and warranty coverage. For more information, contact Hoshizaki Technical Support at 1-800-233-1940.

1. Default Dip Switch Settings

The S1 dip switch settings are factory-set to the following positions:

Dip Switch No.

1

2

3

4

5

6

7

8

9

10

DCM-751B_H

OFF

OFF

OFF

OFF

ON

ON

OFF

ON

OFF

OFF

DCM-751B_H(-OS)

OFF

OFF

OFF

OFF

OFF

ON

OFF

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

Normally off (factory use)

Mechanical Bin Control Shutdown Delay

Bin Control Selector

Continuous Dispensing Timer

(DCM models only, do not adjust on modular appliances)

Drain Frequency Control

Infrared Sensor Shutdown Delay

2. Infrared Sensor Shutdown Delay (S1 dip switch 1, 2, 3)

NOTICE

Do not adjust. Setting not used on this model. When dip switch 7 is off, 1, 2, and 3 are ignored.

Factory set. DCM-751B_H(-OS) does not use an infrared sensor bin control. The appliance uses a mechanical bin control for ice level control.

3. Drain Frequency Control (S1 dip switch 4)

The appliance is factory set for optimum performance with the 1-in-1 drain cycle (S1 dip switch 4 in the "OFF" position). This setting allows for removal of sediment from the evaporator without interrupting the icemaking process. 1-in-12 drain cycle is available.

S1 Dip Switch Setting

Drain Timer Interval

Drain Valve Open

No. 4

 

 

 

 

 

OFF (1-in-1)

1 Hour

2 Seconds

ON (1-in-12)

11 Hours 45 Minutes

10 Minutes

 

 

 