58

Note:

1. The data not in bold should be used for reference only.

2. We reserve the right to make changes in specications and design without prior

notice.
APPROXIMATE Ambient
ICE PRODUCTION Temp. (°F)
PER 24 HR. 70 801 363 757 343 725 329
80 695 315 666 302 639 290
90 612 278 583 265 562 255
lb./day kg/day 100 539 245 517 234 490 222
APPROXIMATE ELECTRIC 70 1292 -- 1306 -- 1319 --
CONSUMPTION 80 1333 -- 1347 -- 1361 --
90 1374 -- 1388 -- 1401 --
watts 100 1414 -- 1426 -- 1439 --
APPROXIMATE WATER 70 96 364 91 344 87 330
CONSUMPTION PER 24 HR. 80 83 316 80 303 77 290
90 73 278 70 265 68 256
gal./day l/day 100 65 245 62 235 59 223
EVAPORATOR OUTLET TEMP. 70 14 -10 14 -10 14 -10
80 14 -10 18 -8 18 -8
90 18 -8 18 -8 20 -7
°F °C 100 20 -7 20 -7 20 -7
HEAD PRESSURE 70 217 15.3 217 15.3 217 15.3
80 253 17.8 253 17.8 253 17.8
90 289 20.3 289 20.3 289 20.3
PSIG kg/cm²G 100 327 23.0 327 23.0 327 23.0
SUCTION PRESSURE 70 32 2.2 32 2.2 32 2.2
80 34 2.4 34 2.4 34 2.4
90 36 2.5 36 2.5 36 2.5
PSIG kg/cm²G 100 38 2.7 38 2.7 38 2.7
TOTAL HEAT OF REJECTION 9,300 BTU/h (AT 90°F /WT 70°F)
Water Temp. (°F)
50 70 90
B. Performance Data

1. DCM-751BAH(-OS)