3. DCM-751BWH
AC SUPPLY VOLTAGE | 115/60/1 |
|
|
|
|
|
|
|
COMPRESSOR | 115 V | 77 LRA |
|
| 11.0 RLA | |||
GEAR MOTOR | 115 V | 3.0 FLA |
|
| 1/4 HP | |||
AGITATING MOTOR | 120 V | 1.8 FLA (TOTAL) | 110 W (TOTAL) | |||||
DISPENSING MOTOR | 115 V | 0.9 FLA |
|
| 55 W | |||
OTHER | 115 V | 0.6 A |
|
|
|
| ||
MAXIMUM FUSE SIZE | 20 A |
|
|
|
|
|
| |
MAX. HACR BREAKER (USA ONLY) | 20 A |
|
|
|
|
|
| |
MAX. CIRC. BREAKER (CANADA ONLY) | 20 A |
|
|
|
|
|
| |
MINIMUM CIRCUIT AMPACITY | 20 A |
|
|
|
|
|
| |
APPROXIMATE ICE PRODUCTION | Ambient |
| WATER TEMP. (°F) |
| ||||
PER 24 HR. | Temp.(°F) |
| 50 |
| 70 |
| 90 |
|
lb./day (kg/day) | 70 |
| *800 (363) |
| 779 (353) |
| 758 (344) |
|
Reference without *marks | 80 |
| 738 (335) |
| 719 (326) |
| 700 (317) |
|
| 90 |
| 681 (309) |
| *685 (311) |
| 646 (293) |
|
SHAPE OF ICE | 100 |
| 629 (285) |
| 612 (278) |
| *563 (255) |
|
Cubelet |
|
|
|
|
|
|
| |
ICE HARDNESS FACTOR | 90% (90/70°F, Conductivity 200 µs/cm) | |||||||
APPROXIMATE STORAGE CAPACITY | 95 lb. |
|
|
|
|
|
| |
ELECTRIC & WATER CONSUMPTION | 90/70°F |
|
| 70/50°F |
|
| ||
ELECTRIC W (kWH/100 lb.) | 1281 (4.77) |
|
|
| 1274 (3.86) |
|
|
|
POTABLE WATER | 82 (12.0) |
|
|
| 96 (12.0) |
|
|
|
| 517 (76) |
|
|
| 380 (47) |
|
|
|
gal./24HR (gal./100 lb.) |
|
|
|
|
|
|
|
|
EXTERIOR DIMENSIONS (WxDxH) | ||||||||
EXTERIOR FINISH | Stainless Steel; Galvanized Steel (Rear) | |||||||
WEIGHT | Net 300 lb. (136 kg), Shipping 345 lb. (156 kg) | |||||||
CONNECTIONS - ELECTRIC | Permanent Connection |
|
|
|
| |||
- WATER SUPPLY | Inlet 1/2" FPT |
|
| Condenser Inlet 1/2" FPT | ||||
- DRAIN | Drip Tray Drain Outlet 3/4" FPT | Condenser Outlet 3/8" FPT | ||||||
| Storage Bin Drain Outlet 3/4" FPT |
|
| |||||
ICE MAKING SYSTEM | Auger Type |
|
|
|
|
|
| |
HARVESTING SYSTEM | Direct Driven Auger (1/4 HP Gear Motor) | |||||||
ICE MAKING WATER CONTROL | Float Switch |
|
|
|
|
|
| |
DISPENSER CONTROL SYSTEM | Push Button |
|
|
|
|
|
| |
COOLING WATER CONTROL | Water Regulating Valve |
|
|
|
| |||
BIN CONTROL SYSTEM | Mechanical Bin Control and Timer |
|
| |||||
COMPRESSOR | Hermetic, Model |
|
| |||||
CONDENSER | Water Cooled, Tube in Tube Type |
|
| |||||
EVAPORATOR | Copper Tube on Cylinder |
|
|
|
| |||
REFRIGERANT CONTROL | Thermostatic Expansion Valve |
|
| |||||
REFRIGERANT CHARGE |
|
| ||||||
DESIGN PRESSURE | High 460 PSIG, Low 290 PSIG |
|
| |||||
P.C. BOARD CIRCUIT PROTECTION | High Voltage Power Protect Relay |
|
| |||||
COMPRESSOR PROTECTION |
|
| ||||||
GEAR MOTOR PROTECTION | ||||||||
REFRIGERANT CIRCUIT PROTECTION |
|
| ||||||
LOW WATER PROTECTION | Float Switch and Timer |
|
|
|
| |||
ACCESSORIES - SUPPLIED | Spare Fuse |
|
|
|
| |||
- OPTIONAL | ||||||||
OPERATING CONDITIONS | VOLTAGE RANGE |
|
| |||||
| AMBIENT TEMP. |
|
| |||||
| WATER SUPPLY TEMP. |
|
| |||||
| WATER SUPPLY PRESSURE |
Note: We reserve the right to make changes in specifications and design without prior notice.
56