2. DCM-751BAH-OS
AC SUPPLY VOLTAGE | 115/60/1 |
|
|
|
|
|
|
|
|
COMPRESSOR | 115 V | 77 LRA |
|
| 11.0 RLA | ||||
GEAR MOTOR | 115 V | 3.0 FLA |
|
| 1/4 HP | ||||
FAN MOTOR | 115 V | 1.0 FLA |
|
| 50 W | ||||
AGITATING MOTOR | 120 V | 1.8 FLA (TOTAL) | 110 W (TOTAL) | ||||||
DISPENSING MOTOR | 115 V | 0.9 FLA |
|
| 55 W | ||||
OTHER | 115 V | 0.6 A |
|
|
|
|
| ||
MAXIMUM FUSE SIZE | 20 A |
|
|
|
|
|
|
| |
MAX. HACR BREAKER (USA ONLY) | 20 A |
|
|
|
|
|
|
| |
MAX. CIRC. BREAKER (CANADA ONLY) | 20 A |
|
|
|
|
|
|
| |
MINIMUM CIRCUIT AMPACITY | 20 A |
|
|
|
|
|
|
| |
APPROXIMATE ICE PRODUCTION | Ambient |
| WATER TEMP. (°F) |
|
| ||||
PER 24 HR. | Temp.(°F) |
| 50 |
| 70 |
| 90 |
|
|
lbs./day (kg/day) | 70 |
| *801 (363) |
| 757 (343) |
| 725 (329) |
|
|
Reference without *marks | 80 |
| 695 (315) |
| 666 (302) |
| 639 (290) |
|
|
| 90 |
| 612 (278) |
| *583 (265) |
| 562 (255) |
|
|
SHAPE OF ICE | 100 |
| 539 (245) |
| 517 (234) |
| *490 (222) |
|
|
Cubelet |
|
|
|
|
|
|
|
| |
ICE HARDNESS FACTOR | 90% (90/70°F, Conductivity 200 µs/cm) | ||||||||
APPROXIMATE STORAGE CAPACITY | 95 lbs. |
|
|
|
|
|
|
| |
ELECTRIC & WATER CONSUMPTION | 90/70°F |
|
| 70/50°F |
|
|
| ||
ELECTRIC W (kWH/100 lbs.) | 1388 (5.94) |
|
|
| 1292 (4.08) |
|
|
|
|
POTABLE WATER | 70 (12.0) |
|
|
| 96 (12.0) |
|
|
|
|
gal./24HR (gal./100 lbs.) |
|
|
|
|
|
|
|
|
|
EXTERIOR DIMENSIONS (WxDxH) |
| ||||||||
EXTERIOR FINISH | Stainless Steel; Galvanized Steel (Rear) | ||||||||
WEIGHT | Net 300 lbs. ( 136 kg ), Shipping 345 lbs. ( 156 kg ) | ||||||||
CONNECTIONS - ELECTRIC | Permanent Connection |
|
|
|
|
| |||
- WATER SUPPLY | Inlet 1/2" FPT |
|
|
|
|
| |||
- DRAIN | Drip Tray Drain Outlet 3/4" FPT |
|
|
| |||||
| Storage Bin Drain Outlet 3/4" FPT |
|
|
| |||||
ICE MAKING SYSTEM | Auger Type |
|
|
|
|
|
|
| |
HARVESTING SYSTEM | Direct Driven Auger (1/4 HP Gear Motor) | ||||||||
ICE MAKING WATER CONTROL | Float Switch |
|
|
|
|
|
|
| |
DISPENSER CONTROL SYSTEM | Photoelectric Sensor (Infrared) |
|
|
| |||||
BIN CONTROL SYSTEM | Mechanical Bin Control and Timer |
|
|
| |||||
COMPRESSOR | Hermetic, Model |
|
|
| |||||
CONDENSER |
|
|
| ||||||
EVAPORATOR | Copper Tube on Cylinder |
|
|
|
|
| |||
REFRIGERANT CONTROL | Thermostatic Expansion Valve |
|
|
| |||||
REFRIGERANT CHARGE |
|
|
| ||||||
DESIGN PRESSURE | High 460 PSIG, Low 290 PSIG |
|
|
| |||||
CONTROL BOARD CIRCUIT PROTECTION | High Voltage Power Protect Relay |
|
|
| |||||
COMPRESSOR PROTECTION |
|
|
| ||||||
GEAR MOTOR PROTECTION | |||||||||
REFRIGERANT CIRCUIT PROTECTION |
|
|
| ||||||
LOW WATER PROTECTION | Float Switch and Timer |
|
|
|
|
| |||
ACCESSORIES - SUPPLIED | Spare Fuse |
|
|
|
|
| |||
- OPTIONAL | |||||||||
OPERATING CONDITIONS | VOLTAGE RANGE |
|
|
| |||||
| AMBIENT TEMP. |
|
| ||||||
| WATER SUPPLY TEMP. |
|
| ||||||
| WATER SUPPLY PRESSURE |
| |||||||
Note: We reserve the right to make changes in specifications and | design without prior | ||||||||
notice. |
|
|
|
|
|
|
|
|
|
55